URM 67 LSF |
Produkt-Name / Code: URM 67 LSF |
Elektrische Leistung |
Anwendung: |
Max.Conductor DC Resistance at 20 ℃( Ω/Km ) 3 8.40 |
5.71 |
For communication and signal control systems. |
Min.Insulation DC Resistance at 20 ℃( MΩ*Km ) >500 |
>500 |
Reference Standard |
Betriebstemperatur( ℃ ) -20-60 |
60 |
Customer's sample spec .and the general standard |
Nennspannung(V) 500 |
1000 |
Kabel Bau |
Capacitance(pF/m) +/-3 |
100 |
Center Dirigent |
Bare Copper |
Strand |
0.77/7 |
Velocity-Verhältnis(%) |
66.60 |
Dia.(mm) |
2.35 |
+/-5%
|
50 |
Isolierung |
Solid PE |
Attenuation at 20 ℃ (dB/100m) |
|
Nom. Dicke(mm) |
2.45 |
200 MHz |
9.8 |
Isolierung Dia. (±0.03mm) |
7.25 |
400 MHz |
15.6 |
Isolations-Color |
Nature |
600 MHz |
20 |
Screening Layer |
Bare Copper braid |
800 MHz |
22.8 |
Bau(stranded) |
16/ 12 /0.18 |
1000 MHz |
28 |
Flechten Abdeckung |
87% |
|
|
Ummantelungen |
LSF PVC |
|
|
Nom. Dicke(mm) |
1.435 |
|
|
Cable Dia.(±0.10mm) |
10.30 |
|
|
Jacke Color |
According to customer |
|
|
Ummantelungen Verbindung |
PVC/LSF/LSOH |
|
|
Core Identification/Color Code |
According to customer request |
|
|
Biegeradius |
6xOverall Diameter |
|
|
Temperatur-Rating |
70C |
|
|
Nennspannung |
300/500V |
|
|
Feuer-Performance |
|
|
Flame Propagation Test to IEC 60332 Part 1 ( PVC /LSOH)
Flame Propagation Test to IEC 60332 Part 1 and Part 3 ( FRPVC/LSFROH )
Determination of the amount Halogen Acid Gas to IEC 60754 Part 1 ( LSOH )
Smoke Density Test to IEC 61034 ( LSOH )
Oxygen Index Test to BS 2863 or ISO 4589-2 ( LSOH )
Temperature Index Test to BS 2782 or ISO 4589-3
( LSOH ) |
|
|