Heim
Über uns
Produkte
Herunterladen
Technische Lib
Kontakt
Anfrage
Sitemap
Links
 

Alarm u. Audio u. Elektronisches Kabe

Belden gleichwertige Kabel

Koaxial-Kabel

SteuerKabel

LWL Kabel

Flexible Kabel

Instrumentation Kabel

Lan Kabel
EnergieKabel
Bahn-Kabel

Robotik

Rolling Stock Kabel
Gummi u. Kran Kabel
Sicherheit Kabel

Telefon Kabel

Flughafen Kabel

Bus-Kabel

Kabelverschraubungen

Daten Kabel

Heat Detection Kabel
Hochtemperatur-Kabel
Highway Kabel
Marine, Öl, Gas & Petrochemie-Kabel
Special Cables
Spiralkabel
Thermoelement-Kabel
Other Cable
     
  Indoor tight buffer fiber optic cable  
Indoor Used Tight Buffered Fiber
Optical Cable
outdoor multi loose tube fiber optic cable
Outdoor Used Multi Loose Tube
Fiber Optical Cable
 
  SteuerKabel

VDE Standard SteuerKabel

CY PVC/PVC /TCWB/ PVC Control Cable

Anwendung:
For use as a measuring, control and signal cable for the machine tool industry, plant construction, heating and air conditioning etc, and are particularly suitable between fixed and mobile equipment. The cable is well protected against electrical interference by the narrow weave tinned copper-wire braid screen, which ensures the undisturbed transmission of pulses and signals in electronic fields.
* Note: should not be used in any installations where the cable is subjected to repetitive flexing.
Standards: Generally BS6500 VDE0250
Dirigent: Class 5 annealed copper conductors to BS6360 / VDE0295
Isolierung: PVC
Bettwäsche: PVC
Flechten: Tinned Copper Wire Braid (TCWB)
Mantel: PVC (Type TM2 to BS7655)
Nennspannung: 300/500V
Temperatur-Rating:
Flexing -15 to +70°C
Static -35 to +70°C
Minimale Biegeradius: 6 x overall diameter
Aderkennzeichnung: Black with White numbers. (3 core and above to include Green/Yellow)
Coloured cores available on request

Current Carrying Capacity (amperes)

Nominal Cross Sectional Area

Single Phase AC or DC

Three Phase AC

mm2

Amps

Amps

0.5

3

3

0.8

6

6

1.0

10

10

1.5

16

16

2.5

25

20

4.0

32

25

6.0

51

43

10.0

70

60

16.0

94

80

The above ratings are based on cable in Free air, in an ambient air temperature of 30°C.

For ambient air temperatures other than 30°C the following rating factors should be applied:
Ratings for cables up to and including 4mm2 are based on 60°C conductor operating temperature with 6mm2 and above based on 70°C operating temperature.

Correction Factors
Cables Up To and Including 4mm2 . Assuming 60°C Conductor Temperature

Ambient Temperature

35°C

40°C

45°C

50°C

55°C

Correction Factor

0.91

0.82

0.71

0.58

0.41

Cables 6mm2 and above. Assuming 70°C Conductor Temperature

Ambient Temperature

35°C

40°C

45°C

50°C

55°C

60°C

Correction Factor

0.91

0.82

0.71

0.58

0.41

0.50

0.5 mm2 conductor CY control cable

Part NO.

CORES & SIZE mm2

O/A
DIA

WEIGHT
KG/KM

CCL-CT-CY-2C0.50SQ

2 X 0.5

5.5

46

CCL-CT-CY-3C0.50SQ

3 X 0.5

5.8

55

CCL-CT-CY-4C0.50SQ

4 X 0.5

6.4

66

CCL-CT-CY-5C0.50SQ

5 X 0.5

7.2

78

CCL-CT-CY-7C0.50SQ

7 X 0.5

8.2

95

CCL-CT-CY-12C0.50SQ

12 X 0.5

10.0

155

CCL-CT-CY-18C0.50SQ

18 X 0.5

11.7

230

CCL-CT-CY-25C0.50SQ

25 X 0.5

13.8

320

0.75 mm2 conductor CY control cable

Part NO.

CORES & SIZE mm2

O/A
DIA

WEIGHT
KG/KM

CCL-CT-CY-2C0.75SQ

2 X 0.75

6.3

55

CCL-CT-CY-3C0.75SQ

3 X 0.75

7.0

67

CCL-CT-CY-4C0.75SQ

4 X 0.75

7.2

80

CCL-CT-CY-5C0.75SQ

5 X 0.75

8.0

100

CCL-CT-CY-7C0.75SQ

7 X 0.75

9.0

130

CCL-CT-CY-12C0.75SQ

12 X 0.75

11.5

210

CCL-CT-CY-18C0.75SQ

18 X 0.75

13.0

260

CCL-CT-CY-25C0.75SQ

25 X 0.75

16.0

430

CCL-CT-CY-34C0.75SQ

34 X 0.75

17.5

515

CCL-CT-CY-42C0.75SQ

42 X 0.75

19.0

600

1.0 mm2 conductor CY control cable

Part NO.

CORES & SIZE mm2

O/A
DIA

WEIGHT
KG/KM

CCL-CT-CY-2C1.00SQ

2 X 1.0

7.0

66

CCL-CT-CY-3C1.00SQ

3 X 1.0

7.3

80

CCL-CT-CY-4C1.00SQ

4 X 1.0

8.0

100

CCL-CT-CY-5C1.00SQ

5 X 1.0

8.5

125

CCL-CT-CY-7C1.00SQ

7 X 1.0

9.2

160

CCL-CT-CY-12C1.00SQ

12 X 1.0

12.5

260

CCL-CT-CY-18C1.00SQ

18 X 1.0

14.5

375

CCL-CT-CY-34C1.00SQ

34 X 1.0

20.0

650

CCL-CT-CY-42C1.00SQ

42 X 1.0

21.5

740

1.5 mm2 conductor CY control cable

Part NO.

CORES & SIZE mm2

O/A
DIA

WEIGHT
KG/KM

CCL-CT-CY-2C1.50SQ

2 X 1.5

7.5

85

CCL-CT-CY-3C1.50SQ

3 X 1.5

8.3

115

CCL-CT-CY-4C1.50SQ

4 X 1.5

8.7

150

CCL-CT-CY-5C1.50SQ

5 X 1.5

9.5

168

CCL-CT-CY-7C1.50SQ

7 X 1.5

10.8

210

CCL-CT-CY-12C1.50SQ

12 X 1.5

13.5

365

CCL-CT-CY-18C1.50SQ

18 X 1.5

16.5

525

CCL-CT-CY-25C1.50SQ

25 X 1.5

19.8

765

CCL-CT-CY-34C1.50SQ

34 X 1.5

22.0

940

CCL-CT-CY-42C1.50SQ

42 X 1.5

23.8

1050

2.5 mm2 conductor CY control cable

Part NO.

CORES & SIZE mm2

O/A
DIA

WEIGHT
KG/KM

CCL-CT-CY-2C2.50SQ

2 X 2.5

9.5

130

CCL-CT-CY-3C2.50SQ

3 X 2.5

10.5

170

CCL-CT-CY-4C2.50SQ

4 X 2.5

11.4

210

CCL-CT-CY-5C2.50SQ

5 X 2.5

12.5

260

CCL-CT-CY-7C2.50SQ

7 X 2.5

14.0

345

4.0 mm2 conductor CY control cable

Part NO.

CORES & SIZE mm2

O/A
DIA

WEIGHT
KG/KM

CCL-CT-CY-3C4.00SQ

3 X 4.0

10.6

265

CCL-CT-CY-4C4.00SQ

4 X 4.0

11.5

350

CCL-CT-CY-5C4.00SQ

5 X 4.0

12.7

480

CCL-CT-CY-7C4.00SQ

7 X 4.0

14.0

6.0 mm2 conductor CY control cable

Part NO.

CORES & SIZE mm2

O/A
DIA

WEIGHT
KG/KM

CCL-CT-CY-4C6.00SQ

4 X 6.0

15.5

550

CCL-CT-CY-5C6.00SQ

5 X 6.0

15.7

CCL-CT-CY-7C6.00SQ

7 X 6.0

16.6

>>Return