BS5308 Part1 Instrumentation Cable Polyethylene Insulated |
VDE Ref Code |
|
|
PVC Sheath Version |
LSOH Sheath Version: |
RE-2Y(St)Y (Overall Screen) |
RE-2Y(St)H (Overall Screen) |
RE-2Y(St)Y PiMF(Individual Screen+Overall Screen) |
RE-2Y(St)HPiMF(Individual Screen+Overall Screen) |
RE-2Y(St)Y-SWA(Overall Screen+Steel Wire Armour) |
RE-2Y(St)-SWA(Overall Screen+Steel Wire Armour) |
RE-2Y(St)Y PiMF-SWA(Individual Screen+Overall Screen+Steel Wire Armour) |
RE-2Y(St)HPiMF-SWA(Individual Screen+Overall Screen+ Steel Wire Armour |
Construction |
|
Construction: Annealed solid copper(Class 1),stranded(Class2), |
Binder tape:A 23 micron p.e.t.p.tape applied with a |
or fiexible(Class 5) to BS5360 . |
minimum 50% overlap. |
Insulation: Polyethylene to BS 6234 Type 03. |
Collective screen: |
Pair identification: |
Aluminium/p.e.t.p.laminated tape applied with the metallic side |
a)Collectively screened cables:Colour coded in |
down in electrical contact with a 0.5mm 2 tinned copper |
. |
accordance with Colour Code Chart 1 on page3 |
drain wire over the p.e.t.p.binder tape. |
b)Individually screened pairs:One blue core and one |
Outer protection: |
|
black core in each pair.Pairs identified by numbered |
Type 1 Extruded flame retardant PVC sheath. |
|
screen isolation tape. |
Type 2 Extruded polyethylene bedding,alvanised steel |
Pair screens |
|
wire armour,extruded flame retardant PVC sheath. |
Aluminium/p.e.t.p.Laminated tape applied with the metallic |
Minimum bending radius: |
side down in electrical contact with a 0.5 mm 2 tinned copper drain wire. |
Type 1 8 x diameter. |
A 23 micron isolation tape is applied over the screening tape with a |
Type 2 12xdiameter. |
minimum 50% overlap. |
|
Voltage rating |
Temperature rating |
300 volt core to earth and 500 volt core to core at maximum |
During Operation:-40 ℃+70℃ |
temperature of 65 ℃ |
During Operation:-0 ℃+50℃ |
These cables are not for direct connection to the public mains supply |
|
|
|
Electrical characteristics |
|
Parameter |
Note |
Unit |
Conductor size |
0.5mm 2
(1/0.8mm) |
0.5mm 2
(16/0.2mm) |
0.75mm 2
(24/0.2mm) |
1.0mm 2
(1/1.13mm) |
1.5mm 2
(7/0.53mm) |
Conductor resistance |
max. |
Ω/Km |
36.8 |
39.7 |
26.5 |
18.2 |
12.3 |
Insulation resistance |
max. |
GΩxKm |
5 |
5 |
5 |
5 |
5 |
Mutual capacitance at 1 kH
-One pair and two pair(Quad)cables with collective screen and all
cables with individually screened pairs
-Cables with only collective screen except one pair and two pair(Quad) |
max. |
pF/m |
115
75 |
115
75 |
115
75 |
115
75 |
115
85 |
Capacitance unbalance at 1 kHz |
max. |
pF/250m |
250 |
250 |
250 |
250 |
250 |
Inductance/resistance ratio(L/R) |
max. |
μH/Ω |
25 |
25 |
25 |
25 |
25 |
Test voltage |
(Core:core) |
- |
V
V |
1000
1000 |
1000
1000 |
1000
1000 |
1000
1000 |
1000
1000 |
(Core:core) |
Rated voltage |
max. |
V |
300/500 |
300/500 |
300/500 |
300/500 |
300/500 |
MULTIPAIR INSTRUMENTATION CABLES(UNARMOURED)
TO BS 5308 PART 1-COLLECTIVELY SCREENED
MULTIPAIR INSTRUMENTATION CABLES(UNARMOURED)TO BS 5308
PART 1 TYPE 1-INDIVIDUAL PAIR AND COLLECTIVELY SCREENED
MULTIPAIR INSTRUMENTATION CABLES(ARMOURED)
TO BS 5308 PART 1 TYPE 2-COLLECTIVELY SCREENED
MULTIPAIR INSTRUMENTATION CABLES(ARMOURED)TO
BS 5308 PART 1 TYPE 2-INDIVIDUAL PAIR AND COLLECTIVELY SCREENED
COLOUR CODE CHART 1
ORDERING OPTIONS
Part 2>> |