Home
Chi siamo
Prodotti
Scaricare
Biblioteca tecnica
Contatto
Richiesta
Mappa del sito 
Collegamenti
 

Allarme & Cavo Audio & Elettronico

Cavo di Equivalente di Belden

Cavo coassiale

Cavo di Controllo

Cavo Fibra Ottica

Cavo Flessibile

Cavo strumentazione

Cavi LAN
Cavo Energia
Cavo Ferroviario

Robotic

Cavo per Materiale Rotabile
Cavo di gomma
Cavo di Sicurezza

Cavo Telefonico

Aeroporto Cavi

Bus Cavi

Serracavi

Data Cable

Calore di rilevamento Cavi
Cavi ad alta temperatura
Cavi autostrada
Marine, OIL,GAS & Petrochemical Cables
Cavi Speciali
Cavi a spirale
Termocoppia Cavi
Mining Cables
Industrial Cables
Undersea Cables
Military Cables
Marine Cables
Hoop-Up Wire
Other Cables
     
  indoor tight buffer fiber optic cable  
Indoor Used Tight Buffered Fiber
Optical Cable
outdoor multi loose tube fiber optic cable
Outdoor Used Multi Loose Tube
Fiber Optical Cable
 
  Marine Cable  

Marine Cable

S10 IYOI(c) 60 V

Applications :

  • These cables are flame retardant, low smoke and halogen free, used for indoor telecommunication.

Standards :

  • IEC 60092-359 IEC 60332-1
    IEC 60332-3-22 IEC 60754-1,2
    IEC 61034-1,2 NEK 606:2004
 

 

Construction :

  • Conductors : Solid tinned copper, 0.5mm.
  • Insulation : Halogen-free thermoplastic compound PE.
  • Twinning : Colour coded cores twisted together. Pairs are cross-stranded to finished cable or 10 pair units. The units are stranded to 20 - 30 - 50 pair cables. 2 pair is stranded as a star quad.
  • Wrapping : Polyester tape.
  • Collective Shielding : The cable core is screened by copper backed polyester tape in contact with a 0.5mm solid tinned drain wire.
  • Bedding : Halogen-free thermoplastic compound, type SHF1, coloured grey.
  • Armour : Copper wire braid.
  • Outer Sheath : Halogen-free thermoplastic compound, type SHF1, coloured grey.

Electrical Characteristics :

  • Nominal Conductor Diameter mm 0.5
    Maximum Resistant@20℃ Ω/km 95
    Nominal Inductance@1KHz MH/km 0.61
    Mutual Capacitance 1-pair cable nF/km 90
    Mutual Capacitance 2-pair cable nF/km 80
    Mutual Capacitance 4-pair and above cable nF/km 70
    Operating Voltage V 60

Mechanical and Thermal Properties :

  • Bending Radius : 8×OD (during installation); 6×OD (fixed installed).
  • Temperature Range : -10℃ ~ +60℃.

Dimensions and Weight :

Construction No. of elements×No. of cores in element×Core diameter
(mm)
Nominal Insulation Thickness
mm
Nominal Sheath Thickness
mm
Nominal Overall Diameter
mm
Nominal Weight
kg/km
Inner Outer
1×2×0.5 0.2 1.2 1.2 8.0 95
2×2×0.5 0.2 1.2 1.2 9.0 110
4×2×0.5 0.2 1.2 1.2 10.0 145
10×2×0.5 0.2 1.5 1.5 12.0 200
20×2×0.5 0.2 1.5 1.5 15.0 330
30×2×0.5 0.2 1.5 1.5 17.0 430
50×2×0.5 0.2 1.5 1.5 20.0 580