Application:
Type SHD-GC is designed for use:
- As a trailing cable on AC mining equipment where service conditions are severe and maximum safety is mandatory (such as power shovels and drag lines in open-pit mines, quarries, gantry cranes and slag reclaiming.)
- For high voltage distribution in underground mines where frequent relocation is necessary.
Specification:
1.Conductor: Stranded soft-drawn coated or uncoated copper
2. Conductor Shield: Extruded semi-conducting layer
3. Insulation: Ethylene propylene rubber (EPR)
4. Insulation Shield: Tinned copper braid over semi-conducting layer
5. Ground Conductors: Two stranded soft-drawn coated copper conductors
6. Ground Check: Stranded bare copper wire with yellow insulation
7. Jacket: Thermoset
8. Temperature: 90°C
9. Voltage: 8000 Volts
10. Color Code:
No.
Cdr. |
Color Code |
Ist
Stripe |
2nd
Stripe |
No.
Cdr. |
Color Code |
Ist
Stripe |
2nd
Stripe |
1 |
Black |
|
|
31 |
Green |
Black |
Orange |
2 |
White |
|
|
32 |
Orange |
Black |
Green |
3 |
Red |
|
|
33 |
Blue |
White |
Orange |
4 |
Green |
|
|
34 |
Black |
White |
Orange |
5 |
Orange |
|
|
35 |
White |
Red |
Orange |
6 |
Blue |
|
|
36 |
Orange |
White |
Blue |
7 |
White |
Black |
|
37 |
White |
Red |
Blue |
8 |
Red |
Black |
|
38 |
Black |
White |
Green |
9 |
Green |
Black |
|
39 |
White |
Black |
Green |
10 |
Orange |
Black |
|
40 |
Red |
White |
Green |
11 |
Blue |
Black |
|
41 |
Green |
White |
Blue |
12 |
Black |
White |
|
42 |
Orange |
Red |
Green |
13 |
Red |
White |
|
43 |
Blue |
Red |
Green |
14 |
Green |
White |
|
44 |
Black |
White |
Blue |
15 |
Blue |
White |
|
45 |
White |
Black |
Blue |
16 |
Black |
Red |
|
46 |
Red |
White |
Blue |
17 |
White |
Red |
|
47 |
Green |
Orange |
Red |
18 |
Orange |
Red |
|
48 |
Orange |
Red |
Blue |
19 |
Blue |
Red |
|
49 |
Blue |
Red |
Orange |
20 |
Red |
Green |
|
50 |
Black |
Orange |
Red |
21 |
Orange |
Green |
|
51 |
White |
Black |
Orange |
22 |
Black |
White |
Red |
52 |
Red |
Orange |
Black |
23 |
White |
Black |
Red |
53 |
Green |
Red |
Blue |
24 |
Red |
Black |
White |
54 |
Orange |
Black |
Blue |
25 |
Green |
Black |
White |
55 |
Blue |
Black |
Orange |
26 |
Orange |
Black |
White |
56 |
Black |
Orange |
Green |
27 |
Blue |
Black |
White |
57 |
White |
Orange |
Green |
28 |
Black |
Red |
Green |
58 |
Red |
Orange |
Green |
29 |
White |
Red |
Green |
59 |
Green |
Black |
Blue |
30 |
Red |
Black |
Green |
60 |
Orange |
Green |
Blue |
11. Industry Approvals: MSHA, ICEA, NEMA
Size
AWG/
MCM |
No.
of
Cond. |
No. of
Strnd** |
Grnd
Cond.
Size
AWG |
Grnd
Check
Size
AWG |
Insul.
Thick.
in. |
Jckt.
Thick.
in. |
Approx.
O.D.
inches |
Amp.*
Rate |
Approx.
Weight
lbs/Mft |
4 |
3 |
133 |
8 |
8 |
.150 |
.205 |
1.94 |
122 |
2230 |
2 |
3 |
133 |
6 |
8 |
.150 |
.220 |
2.12 |
159 |
2830 |
1 |
3 |
133 |
5 |
8 |
.150 |
.220 |
2.21 |
184 |
3180 |
1/0 |
3 |
259 |
4 |
8 |
.150 |
.235 |
2.32 |
211 |
3570 |
2/0 |
3 |
259 |
3 |
8 |
.150 |
.250 |
2.46 |
243 |
4190 |
3/0 |
3 |
427 |
2 |
8 |
.150 |
.250 |
2.62 |
279 |
4880 |
4/0 |
3 |
427 |
1 |
8 |
.150 |
.250 |
2.75 |
321 |
5710 |
250 |
3 |
427 |
1/0 |
8 |
.150 |
.250 |
2.89 |
355 |
6370 |
350 |
3 |
427 |
2/0 |
8 |
.150 |
.280 |
3.20 |
435 |
8333 |
500 |
3 |
427 |
4/0 |
8 |
.150 |
.295 |
3.56 |
536 |
10990 |
|