Cavo Energia
8-15kV XLPE Insulated PVC Sheathed Unarmoured Power Cable 100/133% Insulation Levels
100% Insulation Levels (single conductor)
Direttore |
Insulation
thickness
( mm ) |
Sheath
thickness
( mm ) |
Overall Dia.
approx.
( mm ) |
AC Test
voltage
( kV / 5 min ) |
Cable weight
approx.
( kg / km ) |
Size
(AWG or MCM) |
Construction
( No. / mm ) |
Outside Dia.
( mm ) |
2
1
1/0
2/0
3/0 |
7/2.47
19/1.69
C.C.
C.C.
C.C. |
7.42
8.43
8.53
9.55
10.74 |
4.45
4.45
4.45
4.45
4.45 |
2.03
2.03
2.03
2.03
2.03 |
24.8
25.8
25.9
26.9
28.1 |
27
27
27
27
27 |
882
999
1101
1261
1461 |
4/0
250
300
350
400 |
C.C.
C.C.
C.C.
C.C.
C.C. |
12.07
13.21
14.48
15.65
16.74 |
4.45
4.45
4.45
4.45
4.45 |
2.03
2.03
2.03
2.03
2.03 |
29.5
30.6
31.9
33.0
34.1 |
27
27
27
27
27 |
1707
1925
2194
2460
2733 |
500
550
750
1000 |
C.C.
C.C.
C.C.
C.C. |
18.69
20.65
23.06
26.92 |
4.45
4.45
4.45
4.45 |
2.03
2.03
2.03
2.79 |
36.1
38.0
40.5
46.1 |
27
27
27
27 |
3252
3807
4585
6068 |
100% Insulation Levels (Three conductor)
Direttore |
Insulation
thickness
( mm ) |
Sheath
thickness
( mm ) |
Overall Dia.
approx.
( mm ) |
AC Test
voltage
( kV / 5 min ) |
Cable weight
approx.
( kg / km ) |
Size
(AWG or MCM) |
Construction
( No. / mm ) |
Outside Dia.
( mm ) |
2
1
1/0
2/0
3/0 |
7/2.47
19/1.69
C.C.
C.C.
C.C. |
7.42
8.43
8.53
9.55
10.74 |
4.45
4.45
4.45
4.45
4.45 |
2.79
2.79
2.79
2.79
2.79 |
49.8
52.1
52.3
54.5
57.0 |
27
27
27
27
27 |
2895
3282
3589
4104
4750 |
4/0
250
300
350
400 |
C.C.
C.C.
C.C.
C.C.
C.C. |
12.07
13.21
14.48
15.65
16.74 |
4.45
4.45
4.45
4.45
4.45 |
2.79
2.79
2.79
2.79
2.79 |
59.9
62.4
65.1
67.6
71.7 |
27
27
27
27
27 |
5537
6225
7083
7930
9088 |
133% Insulation Levels (single conductor)
Conductor |
Insulation
thickness
( mm ) |
Sheath
thickness
( mm ) |
Overall Dia.
approx.
( mm ) |
AC Test
voltage
( kV / 5 min ) |
Cable weight
approx.
( kg / km ) |
Size
(AWG or MCM) |
Construction
( No. / mm ) |
Outside Dia.
( mm ) |
1
1/0
2/0
3/0
4/0 |
19/1.69
C.C.
C.C.
C.C.
C.C. |
8.43
8.53
9.55
10.74
12.07 |
5.46
5.46
5.46
5.46
5.46 |
2.03
2.03
2.03
2.03
2.03 |
28.1
28.1
29.2
30.4
31.7 |
33
33
33
33
33 |
1103
1205
1369
1572
1822 |
250
300
350
400
500 |
C.C.
C.C.
C.C.
C.C.
C.C. |
13.21
14.48
15.65
16.74
18.69 |
5.46
5.46
5.46
5.46
5.46 |
2.03
2.03
2.03
2.03
2.03 |
32.8
34.1
35.3
36.4
38.3 |
33
33
33
33
33 |
2044
2317
2587
2863
3388 |
550
750
1000 |
C.C.
C.C.
C.C. |
20.65
23.06
26.92 |
5.46
5.46
5.46 |
2.03
2.79
2.79 |
40.3
44.5
48.3 |
33
33
33 |
3951
4919
6240 |
133% Insulation Levels (Three conductor)
Conductor |
Insulation
thickness
( mm ) |
Sheath
thickness
( mm ) |
Overall Dia.
approx.
( mm ) |
AC Test
voltage
( kV / 5 min ) |
Cable weight
approx.
( kg / km ) |
Size
(AWG or MCM) |
Construction
( No. / mm ) |
Outside Dia.
( mm ) |
1
1/0
2/0
3/0
4/0 |
19/1.69
C.C.
C.C.
C.C.
C.C. |
8.43
8.53
9.55
10.74
12.07 |
5.46
5.46
5.46
5.46
5.46 |
2.79
2.79
2.79
2.79
2.79 |
56.9
57.1
59.3
61.8
64.7 |
33
33
33
33
33 |
3652
3974
4498
5156
5956 |
250
300
350
400 |
C.C.
C.C.
C.C.
C.C. |
13.21
14.48
15.65
16.74 |
5.46
5.46
5.46
5.46 |
2.79
2.79
2.79
2.79 |
67.1
69.9
74.1
76.4 |
33
33
33
33 |
6669
7536
8699
9601 |
|