Home
Chi siamo
Prodotti
Scaricare
Biblioteca tecnica
Contatto
Richiesta
Mappa del sito 
Collegamenti
 

Allarme & Cavo Audio & Elettronico

Cavo di Equivalente di Belden

Cavo coassiale

Cavo di Controllo

Cavo Fibra Ottica

Cavo Flessibile

Cavo strumentazione

Cavi LAN
Cavo Energia
Cavo Ferroviario

Robotic

Cavo per Materiale Rotabile
Cavo di gomma
Cavo di Sicurezza

Cavo Telefonico

Aeroporto Cavi

Bus Cavi

Serracavi

Data Cable

Calore di rilevamento Cavi
Cavi ad alta temperatura
Cavi autostrada
Marine, OIL,GAS & Petrochemical Cables
Cavi Speciali
Cavi a spirale
Termocoppia Cavi
Mining Cables
Industrial Cables
Undersea Cables
Military Cables
Marine Cables
Hoop-Up Wire
Other Cables
     
  indoor tight buffer fiber optic cable  
Indoor Used Tight Buffered Fiber
Optical Cable
outdoor multi loose tube fiber optic cable
Outdoor Used Multi Loose Tube
Fiber Optical Cable
 
Cavo per Materiale Rotabile

Cavo per Materiale Rotabile

FIREROL FRL-TW-05M-OS

     

                                  A.Conduttore       B.Isolamento          C.Schermatura         D.Guaina

Applicazione

-Used as power and control cable for protected installations inside and outside of rail and transport vehicles, where handling and installation cost are an important factor.

-Used in control, auxillary and main circuit wiring such as cable harnesses, switchboards and control panels, driver desks etc.

Edilizia

Conduttore
Tinned annealed copper wires as defined in EN 50306-2

Isolamento
LSZH special compound

Overal screen
Tinned annealed copper wires

Guaina esterna
LSZH special compound (S1 & S2)

Electrical & Mechanical Properties

Nominal Voltage 300/500 V
Maximum Conductor Temperature +120/+150 deg (fixed installation)
Minimum Permissible Ambient Temperature -25/-40 deg (fixed installation)
Bending Radius 10 x Overall Diameter

Chemical & Environmental Properties

EN 60684-2 No fluorine
EN 50305; EN 60811-2-1 Resistance to oil & fuel
EN 50305 Resistance to ozone

Fire Performance for rolling stock application

EN 50306-2 Hazard levels HL1, HL2/HL3, HL4
DIN 5510-2 Protection level 1/2/3/4
BS 6853 Interior use 1a, 1b, II; Exterior use 1a, 1b, II
NF F 16-101 FO

Fire Performance in general

EN 50265-2-1; IEC 60332-1; BS 4066-1 Vertical flame propogation for a single insulated wire or cable
EN 50266-2-4 + EN 50305; IEC 60332-3C; Fire propagation of bunched wires and cables;
VDE 0472 Teil 804; BS 4066-3; NFC 32070  
EN 50268-2; IEC 61034-2; VDE 0472 Teil 816 Smoke density
EN 50267-2-1; IEC 60754-1; VDE 0472 Teil 815 Halogen Free
EN 50267-2-2/3; IEC 60754-2; VDE 0472 Teil 813 Corrosivity of gases (Acidity & Conductivity)
EN 50305; NFX 70-100; NFF 63808; TM1-04; BS6853 Toxicity index
NFF 16101; NFF 63808; BS6853 Smoke index

FRL-TW-05M-OS 300/500 V

NUMBER OF CORES AND NOMINAL CROSS SECTION

MINIMUM THICKNESS OF SHEATH AT ANY POINT

OVERALL DIAMETER

WEIGHT

(mm2)

(mm)

min. (mm)

max. (mm)

(kg/km)

2 x 0.5

0.20

3.5

4.3

30

3 x 0.5

0.20

3.7

4.5

30

4 x 0.5

0.20

4.0

5.0

40

2 x 0.75

0.20

3.9

4.7

30

3 x 0.75

0.20

4.0

5.0

40

4 x 0.75

0.20

4.5

5.5

60

2 x 1

0.20

4.2

5.2

40

3 x 1

0.20

4.5

5.5

55

4 x 1

0.20

5.0

6.0

70

2 x 1.5

0.20

5.1

6.1

60

3 x 1.5

0.20

5.4

6.4

80

4 x 1.5

0.20

6.0

7.0

100

2 x 2.5

0.20

6.4

7.4

90

3 x 2.5

0.20

6.8

7.8

120

4 x 2.5

0.20

7.5

8.5

140