Home
Chi siamo
Prodotti
Scaricare
Biblioteca tecnica
Contatto
Richiesta
Mappa del sito 
Collegamenti
 

Allarme & Cavo Audio & Elettronico

Cavo di Equivalente di Belden

Cavo coassiale

Cavo di Controllo

Cavo Fibra Ottica

Cavo Flessibile

Cavo strumentazione

Cavi LAN
Cavo Energia
Cavo Ferroviario

Robotic

Cavo per Materiale Rotabile
Cavo di gomma
Cavo di Sicurezza

Cavo Telefonico

Aeroporto Cavi

Bus Cavi

Serracavi

Data Cable

Calore di rilevamento Cavi
Cavi ad alta temperatura
Cavi autostrada
Marine, OIL,GAS & Petrochemical Cables
Cavi Speciali
Cavi a spirale
Termocoppia Cavi
Mining Cables
Industrial Cables
Undersea Cables
Military Cables
Marine Cables
Hoop-Up Wire
Other Cables
     
  indoor tight buffer fiber optic cable  
Indoor Used Tight Buffered Fiber
Optical Cable
outdoor multi loose tube fiber optic cable
Outdoor Used Multi Loose Tube
Fiber Optical Cable
 
  Termocoppia Cavi  

Termocoppia Cavi

Part 1 Type 2 XLPE Insulated Individual & Collective Screen SWA LSF Sheathed Thermocouple Cables

Applicazione :
Thermocouple Cables are sensor for measuring temperature, that consists of two dissimilar metals that are joined together at the sensing end. They can be employed as the thermocouple hot junction in addition to serving as the entire wire connection between hot and cold reference junctions.

Types: KX

Direttore: 1.0sqmm class 1 solid copper

Isolamento: XLPE (Cross linked polyethylene)

Core identification: See link below

Screen: IAM (Individual aluminium Mylar) & CAM (Collective aluminium mylar)

Letti: LSZH (Low smoke zero halogen)

Armour/Protection: SWA (Single wire armour)

Sheath/Jacket: LSZH (Low smoke zero halogen)

Colour: Green

Voltage: 300/500V

Norme: BS4937 International thermocouple reference tables. Extension & compensating cables. Tolerances and identification systems

BS5308 Part 1, Insulated cables, instrumentation, PE

Part 1 Type 2 XLPE Insulated Individual & Collective Screen SWA LSF Sheathed Thermocouple Cables

Size sq
(mm)

Stranding
(mm)

RT of Insulation
(mm)
Diameter over Bedding
(mm)
Diameter of Armour Wire

Diameter over Armour
(mm)

RT of Outer Sheath
(mm)

Nominal Overall Diameter
(mm)

App. Weight
(Kg/Km)

0.5

1/0.8

0.5
5.5
0.9

7.3

1.0

9.3

142

1.3

1/1.29

0.6
6.9
0.9

8.7

1.0

10.7

185

0.5 sqmm (1/0.8mm)

No. of Pairs

Nominal Diameter Laid Up Pairs
(mm)

Nominal Diameter Collective Screen
(mm)
RT of Bedding
(mm)
Diameter over Bedding
(mm)

Diameter of Armour Wire
(mm)

Diameter over Armour
(mm)

Nominal Overall Diameter
(mm)

App. Weight
(Kg/Km)

2

7.7

8.7
0.8
10.3

0.9

12.1

14.9

380

5
10.1
11.1
1.2
13.5
1.25
16.0
19.0
660
10
14.9
15.9
1.2
18.3
1.25
20.8
24.2
950
15
15.9
16.9
1.3
19.5
1.6
22.7
27.3
1291
20
19.9
20.9
1.3
23.5
1.6
26.7
30.3
1560
30
23.9
24.9
1.5
27.9
1.6
31.1
34.9
1990

50

31.1

32.1
2.0
36.1

2.0

40.1

44.5

3200

Operating Temperature: Max 105°C, Min -30°C, Min bending 0°C

Min bending radius: 6 X Overall Diameter

Conductor Dimensions

Size & Stranding: 0.5 sqmm (1/0.8mm)