Home
Chi siamo
Prodotti
Scaricare
Biblioteca tecnica
Contatto
Richiesta
Mappa del sito 
Collegamenti
 

Allarme & Cavo Audio & Elettronico

Cavo di Equivalente di Belden

Cavo coassiale

Cavo di Controllo

Cavo Fibra Ottica

Cavo Flessibile

Cavo strumentazione

Cavi LAN
Cavo Energia
Cavo Ferroviario

Robotic

Cavo per Materiale Rotabile
Cavo di gomma
Cavo di Sicurezza

Cavo Telefonico

Aeroporto Cavi

Bus Cavi

Serracavi

Data Cable

Calore di rilevamento Cavi
Cavi ad alta temperatura
Cavi autostrada
Marine, OIL,GAS & Petrochemical Cables
Cavi Speciali
Cavi a spirale
Termocoppia Cavi
Mining Cables
Industrial Cables
Undersea Cables
Military Cables
Marine Cables
Hoop-Up Wire
Other Cables
     
  indoor tight buffer fiber optic cable  
Indoor Used Tight Buffered Fiber
Optical Cable
outdoor multi loose tube fiber optic cable
Outdoor Used Multi Loose Tube
Fiber Optical Cable
 
    Cavo Fibra Ottica 
 

Ordering Options

        Multi Loose Tube Cable

                    CCL-FC-MLA-B-C×D-E-F-G-H×I-J-K-L
A: Loose tube diameter  
  B=2.1mm, C=2.5mm, D=2.8mm, E=3.0mm, F=3.2mm
B: Fiber type  
  0=Fiber and copper conductors in cable
4=50/125 multi-mode fi ber (OM3) per ITU-T G.651
5=50/125 multi-mode fi ber (OM2) per ITU-T G.651
6=62.5/125 multi-mode fi ber (OM1) per ITU-T G.651
7=NZDS SM fi ber per ITU-T G.656.
8=NZDS SM fi ber per ITU-T G.655.
9=Standard SM fi ber per ITU-T G.652.D
Ended with R=Ribbon type fi ber ( Ex: 9R= SM fi ber per G.652.D ribbon type )
C: No. of tubes:  
  1 to 36
D: No. of fi bers per tubes:  
  2 to 12
E: Central member  
  S=Solid steel, SR=Stranded steel, F=Fiber Reinforced Plastic (FRP)
F: Inner jacket options  
  2Y=PE, Y=PVC, H=LSZH
G: Armour options  
  Blank=No armour, T=Corrugated steel tape armour, W=Steel wire armour B=Bronze armour, D=Fiber glass armour; TW= Steel tape + Steel wire armour
H: Jacket material options  
  2Y=PE, Y=PVC, H=LSZH, 11Y=PU, A=Aluminium moisture barrier, T=Anti-termite protection
I: Water-blocking options for cable core  
  X=No water-blocking; J= Water blocking gel in tubes; JD=Water-blocking gel in tubes + dry water blocking in cable core interstices; JJ= Water-blocking gel in tubes and cable core interstices.
J: Water-blocking options for cables with more than one jacket
  X=No water-blocking, J= Water blocking gel between jackets; D=Dry water-blocking between cable jackets;
K: Strength member options  
  A=Aramid yarn, AG=Aramid yarn and fi berglass yarn, G=Fiberlass yarn
L: General options  
  SS=Fig-8 self-supporting UW=Under Water

    ADSS Multi Loose Tube Cable

                 CCL-FC-MLA-B-C-D-E-F-G-H-I-J-K-L-M- ADSS
A: Loose tube diameter  
  B=2.1mm, C=2.5mm, D=2.8mm, E=3.0mm, F=3.2mm
B: Fiber type  
  0=Fiber and copper conductors in cable
4=50/125 multi-mode fi ber(OM3)
5=50/125 multi-mode fi ber(OM2)
6=50/125 multi-mode fi ber(OM1)
7=NZDS SM fi ber per G.656.
8=NZDS SM fi ber per G.655.
9=Standard SM fi ber per G.652.D
Ended with R=Ribbon type fi ber ( Ex: 9R= SM fi ber per G.652.D ribbon type )
C: No. of tubes:  
  01 to 36
D: No. of fi bers per tubes:  
  02 to 12
E: Central member  
  S=Solid steel, SR=Stranded steel, F=Dielectric(FRP)
F: Inner jacket options  
  2Y=PE, Y=PVC, H=LSZH
G: Armour options
  T=Corrugated steel tape armour, B=Bronze, W=Steel wire Armour, WB= Steel Wire
Braid
H: Jacket material options
  2Y=PE, AT= Anti-tracking
I: Water-blocking options for cable core  
  X=No water-blocking; J= Water blocking gel in tubes; JD=Water-blocking gel in tubes + dry water blocking in cable core interstices; JJ= Water-blocking gel in tubes and cable core interstices.
J: Water-blocking options for cables with more than one jacket
  X=No water-blocking, J= Water blocking gel between jackets;
K: Strength member options  
  A=Aramid yarn, AG=Aramid yarn and glass yarn, G=Glass yarn
L: Span Length  
M: Voltage Rating  

    Opgw Type Cable

CCL-FC-A-B-C-D-E-OPGW
A: Fiber type  
  0=Fiber and copper conductors in cable
4=50/125 multi-mode fi ber(OM3)
5=50/125 multi-mode fi ber(OM2)
6=50/125 multi-mode fi ber(OM1)
7=NZDS SM fi ber per G.656.
8=NZDS SM fi ber per G.655.
9=Standard SM fi ber per G.652.D
B: No. of steel tubes:  
  01 to 3
C: No. of fi bers per tubes:  
  02 to 12
D: Cross Sectional Area  
  35=35mm2; 50=50mm2; 70=70mm2; 90=90 mm2; 130=130mm2
E: Rated Voltage  
  66=66KV; 115=115kV; 150=150kV;
250=250kV; 275=275kV; 380=380kV; 500=500kV