Home
Chi siamo
Prodotti
Scaricare
Biblioteca tecnica
Contatto
Richiesta
Mappa del sito 
Collegamenti
 

Allarme & Cavo Audio & Elettronico

Cavo di Equivalente di Belden

Cavo coassiale

Cavo di Controllo

Cavo Fibra Ottica

Cavo Flessibile

Cavo strumentazione

Cavi LAN
Cavo Energia
Cavo Ferroviario

Robotic

Cavo per Materiale Rotabile
Cavo di gomma
Cavo di Sicurezza

Cavo Telefonico

Aeroporto Cavi

Bus Cavi

Serracavi

Data Cable

Calore di rilevamento Cavi
Cavi ad alta temperatura
Cavi autostrada
Marine, OIL,GAS & Petrochemical Cables
Cavi Speciali
Cavi a spirale
Termocoppia Cavi
Mining Cables
Industrial Cables
Undersea Cables
Military Cables
Marine Cables
Hoop-Up Wire
Other Cables
     
  indoor tight buffer fiber optic cable  
Indoor Used Tight Buffered Fiber
Optical Cable
outdoor multi loose tube fiber optic cable
Outdoor Used Multi Loose Tube
Fiber Optical Cable
 
  Industrial Cables  

Industrial Cables

H00V-D

Application and Description

These high flexible earth conductors are used for earthing of portable equipment and short circuiting. These
cables perform a protective function in the live repair of high voltage power supply in railway systems, failing
current equipment, alternating current systems and in networks of transmission and distribution. Because
of that these are designated as safety cables. These earthing cables offer special characteristics with low
weights, high flexibility to a wide temperature range and the behavior in high temperature. The protective
overall PVC jacket assure essential function for proper protection against mechanical and chemical stresses.

Standard and Approval

<HAR> EN61138, VDE-0283 Part-3, DIN 46438 & DIN 46440, CE low voltage directive 73/23/EEC & 93/68/
EEC., ROHS compliant

Cable Construction

- Extra fine bare copper strands
- Strands to DIN VDE 0295, BS 6360, IEC 60228 and HD 383
- Overall bare copper wire braid (for ESUY type)
- PVC transparent jacket TM2
- High stress resistance
- Spark Test 6, 4 & 2 AWG: 5000V
- Spark Test 1 & 2/0 AWG: 6000V
- Spark Test 3/0 - 500 MCM: 8000V

Technical Characteristics

- Working voltage: N/A - earthing only
- Test voltage: 2000 volts
- Minimal bending radius: 12.0 x Ø
- Temperature range: -5º C to +70º C
- Flame retardant: IEC 60332.1
- Insulation resistance: 20 MΩ x km

Cable Parameter

H00V-D (ESEU type)
AWG
No. of Cores x Nominal Cross Sectional Area # x mm²
Nominal Overall Diameter mm
Nominal Copper Weight kg/Km
Nominal Weight kg/Km
6(4200/41)
1 x 16
9.1
194
230
4(3192/38)
1 x 25
10.5
280
335
2(4480/38)
1 x 35
12.5
415
475
1(6383/38)
1 x 50
14.2
585
670
2/0(8918/38)
1 x 70
16.8
820
905
3/0(12100/38)
1 x 95
19.8
1090
1220
4/0(15300/38)
1 x 120
21.5
1360
1505
300MCM(19152/38)
1 x 150
24
1650
1940
350MCM(23580/38)
1 x 185
27.6
2150
2390
500MCM(30600/38)
1 x 240
31
2750
3090

H00V-D (ESY type)
AWG
No. of Cores x Nominal Cross Sectional Area # x mm²
Nominal Overall Diameter mm
Nominal Copper Weight kg/Km
Nominal Weight kg/Km
1 x 16
8.5
155
185
4(798/32)
1 x 25
10.0
240
270
2(1120/32)
1 x 35
12.5
336
390
1(1617/32)
1 x 50
14.0
480
575
2/0(2254/32)
1 x 70
17.2
672
810
3/0(3087/32)
1 x 95
19.5
912
1080
4/0(3822/32)
1 x 120
22.8
1152
1320
300MCM(4802/32)
1 x 150
25.4
1440
1680