Home
Chi siamo
Prodotti
Scaricare
Biblioteca tecnica
Contatto
Richiesta
Mappa del sito 
Collegamenti
 

Allarme & Cavo Audio & Elettronico

Cavo di Equivalente di Belden

Cavo coassiale

Cavo di Controllo

Cavo Fibra Ottica

Cavo Flessibile

Cavo strumentazione

Cavi LAN
Cavo Energia
Cavo Ferroviario

Robotic

Cavo per Materiale Rotabile
Cavo di gomma
Cavo di Sicurezza

Cavo Telefonico

Aeroporto Cavi

Bus Cavi

Serracavi

Data Cable

Calore di rilevamento Cavi
Cavi ad alta temperatura
Cavi autostrada
Marine, OIL,GAS & Petrochemical Cables
Cavi Speciali
Cavi a spirale
Termocoppia Cavi
Mining Cables
Industrial Cables
Undersea Cables
Military Cables
Marine Cables
Hoop-Up Wire
Other Cables
     
  indoor tight buffer fiber optic cable  
Indoor Used Tight Buffered Fiber
Optical Cable
outdoor multi loose tube fiber optic cable
Outdoor Used Multi Loose Tube
Fiber Optical Cable
 
  Industrial Cables  

Industrial Cables

H01N2-D/E(NSKFFÖU)

Application and Description

These cables are used as a connection between the welding generator, the hand-electrode and the work
piece. For use in the automobile industry, ship building, transport and conveyor systems, tool making
machinery, welding robots etc. These cables retain their high flexibility even under influence of ozone, light,
oxygen, protective gases, oil and petrol. Robust cable structure of these cables makes them resistant to low
and high temperature, fire, ozone and radiation, oils, acids, fats and petrols. These cables are also ideal for
outside installation in dry, moist and wet areas.

Standard and Approval

<HAR> HD22.6 S2, VDE-0282 Part-6, IEC 60332.3, IEC 60754.1, UNEL 35368, CEI 20-22 II, CEI 20-38, CE
low voltage directive 73/23/EEC & 93/68/EEC., ROHS compliant

Cable Construction

- Extra fine bare copper strands
- Strands to DIN VDE 0295, BS 6360, IEC 60228 and HD 383
- Strands to VDE-0295 as listed below
- Synthetic or paper separator over core
- Polychloroprene rubber (neoprene) jacket EM5

Technical Characteristics

- Working voltage: 100/100 volts
- Test voltage: 1000 volts
- Flexing bending radius: 12.0 x Ø
- Fixed bending radius: 7.5 x Ø
- Flexing Temperature: -25º C to +80º C
- Fixed Temperature: -40º C to +80º C
- Flame retardant: IEC 60332.1

           

Cable Parameter

Cables with Standard and Approval flexibility
No. of Cores x Nominal Cross Sectional Area # x mm²
Nominal Thickness of Insulation mm
Nominal Overall Diameter mm
Nominal Copper Weight kg/Km
Nominal Weight kg/Km
1 x 10
2.0
7.7-9.7
96
135
6(512/32)
1 x 16
2.0
8.8-11.0
154
205
4(800/32)
1 x 25
2.0
10.1-12.7
240
302
2(1120/32)
1 x 35
2.0
11.4-14.2
336
420
1(1600/32)
1 x 50
2.2
13.2-16.5
480
586
2/0(2240/32)
1 x 70
2.4
15.3-19.2
672
798
3/0(3024/32)
1 x 95
2.6
17.1-21.4
912
1015
4/0(614/24)
1 x 120
2.8
19.2-24.0
1152
1310
300MCM(765/24)
1 x 150
3.0
21.2-26.4
1440
1620
350MCM(944/24)
1 x 185
3.2
23.1-28.9
1776
1916
500MCM(1225/24)
1 x 240
3.4
25.0-29.5
2304
2540

 

Cables with extreme high flexibility
No. of Cores x Nominal Cross Sectional Area # x mm²
Nominal Thickness of Insulation mm
Nominal Overall Diameter mm
Nominal Copper Weight kg/Km
Nominal Weight kg/Km
8(566/35)
1 x 10
1.2
6.2-7.8
96
119
6(903/35)
1 x 16
1.2
7.3-9.1
154
181
4(1407/35)
1 x 25
1.2
8.6-10.8
240
270
2(1974/35)
1 x 35
1.2
9.8-12.3
336
363
1(2830/35)
1 x 50
1.5
11.9-14.8
480
528
2/0(3952/35)
1 x 70
1.8
13.6-17.0
672
716
3/0(5370/35)
1 x 95
1.8
15.6-19.5
912
1012
4/0(3819/32)
1 x 120
1.8
17.2-21.6
1152
1190
300MCM(4788/32)
1 x 150
1.8
18.8-23.5
1440
1305
500MCM(5852/32)
1 x 185
1.8
20.4-25.5
1776
1511