Home
Chi siamo
Prodotti
Scaricare
Biblioteca tecnica
Contatto
Richiesta
Mappa del sito 
Collegamenti
 

Allarme & Cavo Audio & Elettronico

Cavo di Equivalente di Belden

Cavo coassiale

Cavo di Controllo

Cavo Fibra Ottica

Cavo Flessibile

Cavo strumentazione

Cavi LAN
Cavo Energia
Cavo Ferroviario

Robotic

Cavo per Materiale Rotabile
Cavo di gomma
Cavo di Sicurezza

Cavo Telefonico

Aeroporto Cavi

Bus Cavi

Serracavi

Data Cable

Calore di rilevamento Cavi
Cavi ad alta temperatura
Cavi autostrada
Marine, OIL,GAS & Petrochemical Cables
Cavi Speciali
Cavi a spirale
Termocoppia Cavi
Mining Cables
Industrial Cables
Undersea Cables
Military Cables
Marine Cables
Hoop-Up Wire
Other Cables
     
  indoor tight buffer fiber optic cable  
Indoor Used Tight Buffered Fiber
Optical Cable
outdoor multi loose tube fiber optic cable
Outdoor Used Multi Loose Tube
Fiber Optical Cable
 
  Industrial Cables  

Industrial Cables

H05BN4-F

Application and Description

These EPR (ethylen-propylen rubber) insulated and CSP (chlorosulphonated polyethylene rubber or similar)
sheathed electric cables can be used either in dry, humid or wet places or in contact with oil or grease, in
weather conditions and under weak mechanical stress, for example for power supply to small appliances
in industrial plants, machine shops, heating plates, portable lamps, farming equipment etc. They are also
suitable for caravans and camping equipment... The maximum conductor temperature in normal use: 90°C.
While high temperature use, skin contact must be avoided.

Standard and Approval

<HAR> CENELEC HD 22.12 S1, CEI 20-19/12, CEI 20-35 (EN 60332-1), BS6500, BS7919,
ROHS compliant, VDE 0282 Part-12, IEC 60245-4, CE Low-Voltage

Cable Construction

- Fine bare copper strands
- Strands to VDE-0295 Class-5, IEC 60228 Class-5
- EPR(Ethylene Propylene Rubber) rubber EI7 insulation
- Color code VDE-0293-308
- CSP(Chlorosulphonated Polyethylene) outer jacket EM7

Technical Characteristics

- Working voltage: 300/500 volts
- Test voltage: 2000 volts
- Flexing bending radius: 6.0 x Ø
- Fixed bending radius: 4.0 x Ø
- Temperature Range: -20º C to +90º C
- Maximum Short Circuit Temperature: +250º C
- Flame retardant: IEC 60332.1
- Insulation resistance: 20 MΩ x km

           

Cable Parameter

AWG
No. of Cores x Nominal Cross Sectional Area # x mm²
Nominal Thickness of Insulation mm
Nominal Thickness of Sheath mm
Nominal Overall Diameter mm
Nominal Copper Weight kg/Km
Nominal Weight kg/Km
2 x 0.75
0.8
6.1
29
54
18(24/32)
3 x 0.75
0.6
0.9
6.7
43
68
18(24/32)
4 x 0.75
0.6
0.9
7.3
58
82
18(24/32)
5 x 0.75
0.6
1.0
8.1
72
108
2 x 1
0.6
0.9
6.6
19
65
17(32/32)
3 x 1
0.6
0.9
7.0
29
78
17(32/32)
4 x 1
0.6
0.9
7.6
38
95
17(32/32)
5 x 1
0.6
1.0
8.5
125