Home
Chi siamo
Prodotti
Scaricare
Biblioteca tecnica
Contatto
Richiesta
Mappa del sito 
Collegamenti
 

Allarme & Cavo Audio & Elettronico

Cavo di Equivalente di Belden

Cavo coassiale

Cavo di Controllo

Cavo Fibra Ottica

Cavo Flessibile

Cavo strumentazione

Cavi LAN
Cavo Energia
Cavo Ferroviario

Robotic

Cavo per Materiale Rotabile
Cavo di gomma
Cavo di Sicurezza

Cavo Telefonico

Aeroporto Cavi

Bus Cavi

Serracavi

Data Cable

Calore di rilevamento Cavi
Cavi ad alta temperatura
Cavi autostrada
Marine, OIL,GAS & Petrochemical Cables
Cavi Speciali
Cavi a spirale
Termocoppia Cavi
Mining Cables
Industrial Cables
Undersea Cables
Military Cables
Marine Cables
Hoop-Up Wire
Other Cables
     
  indoor tight buffer fiber optic cable  
Indoor Used Tight Buffered Fiber
Optical Cable
outdoor multi loose tube fiber optic cable
Outdoor Used Multi Loose Tube
Fiber Optical Cable
 
  Industrial Cables  

Industrial Cables

H05G-U/H07G-U/R

Application and Description

These cables are recommended for the internal wiring of switchboards and distributor boards as well as
in operating parts in or on lights. The higher temperature range allows for connections to heaters with an
alternating nominal voltage of 1000V. or direct nominal voltage of 750V. These cables are all allowed for
laying in tubes in and under plaster.

Standard and Approval

<HAR> HD 22.7 S2, VDE-0282 Part-7, CEI 20-19/7, CEI 20-35(EN60332-1), CE Low Voltage Directive
73/23/EEC and 93/68/EEC, ROHS compliant

Cable Construction

- Solid bare copper / strands
- Strands to VDE-0295 Class-1/2, IEC 60228 Class-1/2
- Rubber compound type EI3 (EVA) to DIN VDE 0282 part 7 insulation
- Cores to VDE-0293 colors

          

Technical Characteristics

- Working voltage: 300/500v (H05G-U), 450/750v (H07G-U/R)
- Test voltage: 2000volts (H05G-U), 2500 volts (H07G-U/R)
- Flexing bending radius: 7 x Ø
- Static bending radius: 7 x Ø
- Flexing temperature: -25º C to +110º C
- Static temperature: -40º C to +110º C
- Short circuit Temperature: +160º C
- Flame retardant: IEC 60332.1
- Insulation resistance: 10 MΩ x km

           

Cable Parameter

AWG
No. of Cores x Nominal Cross Sectional Area # x mm²
Nominal Thickness of Insulation
mm
Nominal
Overall iameter mm
Nominal Copper Weight kg/km
Nominal Weight kg/km
H05G-U
20
1×0.5
0.6
2.1
4.8
9
18
1×0.75
0.6
2.3
7.2
12
17
1×1
0.6
2.5
9.6
15
H07G-U
16
1×1.5
0.8
3.1
14.4
21
14
1×2.5
0.9
3.6
24
32
12
1×4
1
4.3
38
49
H07G-R
10(7/18)
1×6
1
5.2
58
70
8(7/16)
1×10
1.2
6.5
96
116
6(7/14)
1×16
1.2
7.5
154
173
4(7/12)
1×25
1.4
9.2
240
268
2(7/10)
1×35
1.4
10.3
336
360
1(7/13)
1×50
1.6
12
480
487