Home
Chi siamo
Prodotti
Scaricare
Biblioteca tecnica
Contatto
Richiesta
Mappa del sito 
Collegamenti
 

Allarme & Cavo Audio & Elettronico

Cavo di Equivalente di Belden

Cavo coassiale

Cavo di Controllo

Cavo Fibra Ottica

Cavo Flessibile

Cavo strumentazione

Cavi LAN
Cavo Energia
Cavo Ferroviario

Robotic

Cavo per Materiale Rotabile
Cavo di gomma
Cavo di Sicurezza

Cavo Telefonico

Aeroporto Cavi

Bus Cavi

Serracavi

Data Cable

Calore di rilevamento Cavi
Cavi ad alta temperatura
Cavi autostrada
Marine, OIL,GAS & Petrochemical Cables
Cavi Speciali
Cavi a spirale
Termocoppia Cavi
Mining Cables
Industrial Cables
Undersea Cables
Military Cables
Marine Cables
Hoop-Up Wire
Other Cables
     
  indoor tight buffer fiber optic cable  
Indoor Used Tight Buffered Fiber
Optical Cable
outdoor multi loose tube fiber optic cable
Outdoor Used Multi Loose Tube
Fiber Optical Cable
 
  Industrial Cables  

Industrial Cables

H05RN-F/H05RNH2-F

Application and Description

These cables are flexible, mainly recommended for use in electrical equipment under low stress in dry, damp
and wet areas in indoor or outdoor environments. Commonly used for connection of electrical appliances
when exposed to low mechanical strain in household, offices and for light utilities. Anywhere where there is
minimal physical damage. Also suitable for fixed installation in furniture, decorative coverings, wall partitions
and pre-fabricated building parts. Max operating voltage in single or three phase system is Uo/U 318/550
volts. In a direct current system max operating voltage is Uo/U 413/825 volts. They are ozone resistant, oil &
fat resistant

Standard and Approval

<HAR> HD22.4 S3, VDE-0282 Part-4, CEI 20-19 p.4,CE low voltage directive 73/23/EEC & 93/68/EEC.,
IEC 60245-4, ROHS compliant

Cable Construction

- Fine bare copper strands
- Strands to VDE-0295 Class-5, IEC 60228 Class-5
- Rubber core insulation EI4 to VDE-0282 Part-1
- Color code VDE-0293-308
- Green-yellow grounding, 3 conductors and above
- Polychloroprene rubber (neoprene) jacket EM2

          

Technical Characteristics

- Working voltage: 300/500 volts
- Test voltage: 2000 volts
- Flexing bending radius: 7.5 x Ø
- Fixed bending radius: 4.0 x Ø
- Temperature Range: -30º C to +60º C
- Short circuit temperature: +200 º C
- Flame retardant: IEC 60332.1
- Insulation resistance: 20 MΩ x km

          

Cable Parameter

AWG
No. of Cores x Nominal Cross Sectional Area # x mm²
Nominal Thickness of Insulation mm
Nominal Thickness of Sheath mm
Nominal Overall Diameter mm min-max
Nominal Copper Weight kg/Km
Nominal Weight kg/Km
H05RN-F
18(24/32)
2 x 0.75
0.6
0.8
5.7 - 7.4
14.4
80
18(24/32)
3 x 0.75
0.6
0.9
6.2 - 8.1
21.6
95
18(24/32)
4 x 0.75
0.6
0.9
6.8 - 8.8
30
105
17(32/32)
2 x 1
0.6
0.9
6.1 - 8.0
19
95
17(32/32)
3 x 1
0.6
0.9
6.5 - 8.5
29
115
17(32/32)
4 x 1
0.6
0.9
7.1 – 9.2
38
142
16(30/30)
3 x 1.5
0.8
1.0
8.6 - 11.0
29
105
16(30/30)
4 x 1.5
0.8
1.1
9.5 - 12.2
39
129
16(30/30)
5 x 1.5
0.8
1.1
10.5 - 13.5
48
153
H05RNH2-F
16(30/30)
2 x 1.5
0.6
0.8
5.25±0.15x13.50±0.30
14.4
80
14(50/30)
2 x 2.5
0.6
0.9
5.25±0.15x13.50±0.30
21.6
95