Home
Chi siamo
Prodotti
Scaricare
Biblioteca tecnica
Contatto
Richiesta
Mappa del sito 
Collegamenti
 

Allarme & Cavo Audio & Elettronico

Cavo di Equivalente di Belden

Cavo coassiale

Cavo di Controllo

Cavo Fibra Ottica

Cavo Flessibile

Cavo strumentazione

Cavi LAN
Cavo Energia
Cavo Ferroviario

Robotic

Cavo per Materiale Rotabile
Cavo di gomma
Cavo di Sicurezza

Cavo Telefonico

Aeroporto Cavi

Bus Cavi

Serracavi

Data Cable

Calore di rilevamento Cavi
Cavi ad alta temperatura
Cavi autostrada
Marine, OIL,GAS & Petrochemical Cables
Cavi Speciali
Cavi a spirale
Termocoppia Cavi
Mining Cables
Industrial Cables
Undersea Cables
Military Cables
Marine Cables
Hoop-Up Wire
Other Cables
     
  indoor tight buffer fiber optic cable  
Indoor Used Tight Buffered Fiber
Optical Cable
outdoor multi loose tube fiber optic cable
Outdoor Used Multi Loose Tube
Fiber Optical Cable
 
  Industrial Cables  

Industrial Cables

H05RR-F

Application and Description

These cables are flexible rubber insulated; rubber jacketed harmonized cord, recommended for use in
equipment, which is subject to light and medium stresses in both dry and damp environments. For use with
electronics and electrical equipment such as appliances, small hand tools and office equipment They can
be found in flat irons, soldering irons, kitchen aids, toasters, stoves and in connections with light commercial
electric tools. Also suitable for fixed installation in furniture, decorative coverings, wall partitions and prefabricated building parts. Max operating voltage in single or three phase system is Uo/U 300/500 volts. In a
direct current system max operating voltage is Uo/U 413/825 volts. Outdoor use is permitted only for a short
time. They are ozone resistant, oil & fat resistant.

Standard and Approval

<HAR> HD22.4 S3, VDE-0282 Part-4, CEI 20-19/4 / 20-35 (EN60332-1),
CE low voltage directive 73/23/EEC & 93/68/EEC., IEC 60245-4, ROHS compliant

Cable Construction

- Fine bare copper strands
- Strands to VDE-0295 Class-5, IEC 60228 Class-5
- Rubber core insulation EI4 to VDE-0282 Part-1
- Color code VDE-0293-308 and HD 186
- Green-yellow grounding, 3 conductors and above
- Polychloroprene rubber (neoprene) jacket EM3

Technical Characteristics

- Working voltage: 300/500 volts
- Test voltage: 2000 volts
- Flexing bending radius: 8 x Ø
- Fixed bending radius: 6 x Ø
- Temperature range: -30º C to +60º C
- Short circuit temperature: +200 º C
- Flame retardant: IEC 60332.1
- Insulation resistance: 20 MΩ x km

          

Cable Parameter

AWG
No. of Cores x Nominal Cross Sectional Area # x mm²
Nominal Thickness of Insulation mm
Nominal Thickness of Sheath mm
Nominal Overall Diameter mm min-max
Nominal Copper Weight kg/Km
Nominal Weight kg/Km
18(24/32)
2 x 0.75
0.6
0.8
5.7-7.4
14.4
61
18(24/32)
3 x 0.75
0.6
0.9
6.2-8.1
21.6
75
18(24/32)
4 x 0.75
0.6
0.9
6.8-8.8
28.8
94
18(24/32)
5 x 0.75
0.6
1.0
7.6-9.9
36.0
110
17(32/32)
2 x 1
0.6
0.9
6.1-8.0
19.0
73
17(32/32)
3 x 1
0.6
0.9
6.5-8.5
29.0
86
17(32/32)
4 x 1
0.6
0.9
7.1-9.3
38.4
105
17(32/32)
5 x 1
0.6
1.0
8.0-10.3
48.0
130
16(30/30)
2 x 1.5
0.8
1.0
7.6-9.8
29.0
115
16(30/30)
3 x 1.5
0.8
1.0
8.0-10.4
43.0
135
16(30/30)
4 x 1.5
0.8
1.1
9.0-11.6
58.0
165
16(30/30)
5 x 1.5
0.8
1.1
9.8-12.7
72.0
190
14(50/30)
2 x 2.5
0.9
1.1
9.0-11.6
48.0
160
14(50/30)
3 x 2.5
0.9
1.1
9.6-12.4
72.0
191
14(50/30)
4 x 2.5
0.9
1.2
10.7-13.8
96.0
235
14(50/30)
5 x 2.5
0.9
1.3
11.9-15.3
120.0
285