  indoor tight buffer fiber optic cable  
Indoor Used Tight Buffered Fiber
Optical Cable
outdoor multi loose tube fiber optic cable
Outdoor Used Multi Loose Tube
Fiber Optical Cable
 
  Industrial Cables  

Industrial Cables

H05V-U/H07V-U

Application and Description

H05 V-U/(H)05 V-U

These insulated wires are determined for the installation to the inside of apparatus as well as for the
protective laying to the lightings, in dry rooms, in production facilities, switch and distributor boards, in tubes,
under and surface mounting of plasters.

H07 V-U/(H)07 V-U
These insulated wires are suitable for laying tubes, under and surface mounting of plasters and also in
closed installation conduits. These are not allowed to install for direct laying in cable trays, channels or
tanks. These types are permitted for the inner wiring of equipment, distributor and switchboards and also for
protective laying to the lightings with a nominal voltage up to 1000 V alternating current or up to 750 V direct
current against ground..

Standard and Approval

<HAR> HD 21.3 S3, VDE-0281 Part-3, CEI20-20/3,
CE Low Voltage Directive 73/23/EEC and 93/68/EEC, ROHS compliant

Cable Construction

- Solid bare copper single wire
- Solid to DIN VDE 0295 cl-1 and IEC 60228 cl-1
- Special PVC TI1 core insulation
- Cores to VDE-0293 colors on chart
- H05V-U (20, 18 & 17 AWG)
- H07V-U (16 AWG and Larger)

Technical Characteristics

- Working voltage: 300/500v (H05V-U)
- Working voltage: 450/750v (H07V-U)
- Test voltage: 2000V(H05V-U)/2500V (H07V-U)
- Flexing bending radius: 15 x Ø
- Static bending radius: 15 x Ø
- Flexing temperature: -5º C to +70º C
- Static temperature: -30º C to +90º C
- Short circuit temperature: +160º C
- Flame retardant: IEC 60332.1
- Insulation resistance: 10 MΩ x km

           

Cable Parameter

AWG
No. of Cores x Nominal Cross Sectional Area # x mm²
Nominal Thickness of Insulation mm
Nominal Overall Diameter
mm
Nominal Copper Weight kg/Km
Nominal Weight kg/Km
20
1 x 0.5
0.6
2.1
4.8
9
18
1 x 0.75
0.6
2.2
7.2
11
17
1 x 1
0.6
2.4
9.6
14
16
1 x 1.5
0.7
2.9
14.4
21
14
1 x 2.5
0.8
3.5
24.0
33
12
1 x 4
0.8
3.9
38.0
49
10
1 x 6
0.8
4.5
58.0
69
8
1 x 10
1.0
5.7
96.0
115