Home
Chi siamo
Prodotti
Scaricare
Biblioteca tecnica
Contatto
Richiesta
Mappa del sito 
Collegamenti
 

Allarme & Cavo Audio & Elettronico

Cavo di Equivalente di Belden

Cavo coassiale

Cavo di Controllo

Cavo Fibra Ottica

Cavo Flessibile

Cavo strumentazione

Cavi LAN
Cavo Energia
Cavo Ferroviario

Robotic

Cavo per Materiale Rotabile
Cavo di gomma
Cavo di Sicurezza

Cavo Telefonico

Aeroporto Cavi

Bus Cavi

Serracavi

Data Cable

Calore di rilevamento Cavi
Cavi ad alta temperatura
Cavi autostrada
Marine, OIL,GAS & Petrochemical Cables
Cavi Speciali
Cavi a spirale
Termocoppia Cavi
Mining Cables
Industrial Cables
Undersea Cables
Military Cables
Marine Cables
Hoop-Up Wire
Other Cables
     
  indoor tight buffer fiber optic cable  
Indoor Used Tight Buffered Fiber
Optical Cable
outdoor multi loose tube fiber optic cable
Outdoor Used Multi Loose Tube
Fiber Optical Cable
 
  Industrial Cables  

Industrial Cables

H05V2-K UL/H07V2-K UL

Application and Description

H05V2-K UL / H07V2-K UL are internationally approved harmonized, UL/CSA and AWM/MTW approved
PVC European flexible single-conductor wires with increased temperature range for HAR/IEC and higher
working voltage for UL-AWM. Due to these increases it is suitable for use in connections and internal
wirings of frequency converters. Can be found in appliance wiring and machine tool wiring as well as in
control systems. They may also be used in pipes and flexible conduits. Recommended for the internal
wiring of apparatus, switchboards and distributor boards in electronic and electrical equipment designed for
international use in North American & European countries and for MRO replacement of international made
equipment wire.

Standard and Approval

<HAR> HD 21.7 S2, <HAR> H05V2-K / H07V2-K, VDE-0281 Part-3,
UL-Standard and Approval 1063 MTW, UL-AWM Style 10269, CSA TEW, CSA-AWM 1 A/B, FT-1,
CE Low Voltage Directive 73/23/EEC and 93/68/EEC, ROHS compliant

Cable Construction

- Fine tinned copper strands
- Strands to VDE-0295 Class-5, IEC 60228 Class-5
- Special PVC core insulation
- Cores to VDE-0293 colors on chart
- H05V2-K UL (22, 20 & 18 AWG)
- H07V2-K UL (16 AWG and Larger)
- X05V2-K UL & X07V2-K UL for non-HAR colors

               

Technical Characteristics

- Working voltage: 300/500v (H05V2-K UL)
- Working voltage: 450/750v (H07V2-K UL)
- Working voltage UL(MTW) & CSA: 600v
- Working voltage UL (AWM): 1000v
- Test voltage: 2500 volts (4000 volts UL)
- Flexing/Static bending radius: 10-15 x Ø
- Temperature HAR/IEC: -40º to +90º C
- Temperature UL-AWM: -40º to +105º C
- Temperature UL-MTW: -40º C to +90º C
- Temperature CSA-TEW: -40º C to +105º C
- Flame retardant: IEC 60332.1, FT-1, UL VW-1
- Insulation resistance: 20 MΩ x km

           

Cable Parameter

AWG
No. of Cores x Nominal Cross Sectional Area # x mm²
Nominal Thickness of Insulation mm
Nominal Overall Diameter mm
Nominal Copper Weight kg/Km
Nominal Weight kg/Km
20(16/32)
1 x 0.5
0.6
2.5
4.8
11
18(24/32)
1 x 0.75
0.6
2.7
7.2
14
17(32/32)
1 x 1
0.6
2.9
9.6
16
16(30/30)
1 x 1.5
0.7
3.1
14.4
20
14(50/30)
1 x 2.5
0.8
3.7
24
32
12(56/28)
1 x 4
0.8
4.4
38
50
10(84/28)
1 x 6
0.8
4.9
58
66
8(80/26)
1 x 10
1.0
6.8
96
121
6(128/26)
1 x 16
1.0
8.9
154
211
4 (200/26)
1 x 25
1.2
10.1
240
303
2 (280/26)
1 x 35
1.2
11.4
336
407
1 (400/26)
1 x 50
1.4
14.1
480
600
2/0 (356/24)
1 x 70
1.4
15.8
672
790
3/0 (485/24)
1 x 95
1.6
18.1
912
1067
4/0 (614/24)
1 x 120
1.6
19.5
1115
1277