Home
Chi siamo
Prodotti
Scaricare
Biblioteca tecnica
Contatto
Richiesta
Mappa del sito 
Collegamenti
 

Allarme & Cavo Audio & Elettronico

Cavo di Equivalente di Belden

Cavo coassiale

Cavo di Controllo

Cavo Fibra Ottica

Cavo Flessibile

Cavo strumentazione

Cavi LAN
Cavo Energia
Cavo Ferroviario

Robotic

Cavo per Materiale Rotabile
Cavo di gomma
Cavo di Sicurezza

Cavo Telefonico

Aeroporto Cavi

Bus Cavi

Serracavi

Data Cable

Calore di rilevamento Cavi
Cavi ad alta temperatura
Cavi autostrada
Marine, OIL,GAS & Petrochemical Cables
Cavi Speciali
Cavi a spirale
Termocoppia Cavi
Mining Cables
Industrial Cables
Undersea Cables
Military Cables
Marine Cables
Hoop-Up Wire
Other Cables
     
  indoor tight buffer fiber optic cable  
Indoor Used Tight Buffered Fiber
Optical Cable
outdoor multi loose tube fiber optic cable
Outdoor Used Multi Loose Tube
Fiber Optical Cable
 
  Industrial Cables  

Industrial Cables

H05VV-F/SJT

Application and Description

These cables are suited to be used for cooking and heating apparatus under the condition that cable does
not come in direct contact with hot parts of the apparatus and no other influences or heat. The cables
are suitable for fixed installation in furniture, partition walls, decoration covering and in hollow spaces of
prefabricated building parts. They are not suitable for use in open air, in industries (also permitted to tailor
workshops and of that kind) and in agriculture plants and for connecting commercial electrical tools.

Standard and Approval

<HAR> HD21.5 S3, VDE-0281 Part-5 & Part-2, UL Style 62 (SJT), VW-1, CSA 22.2 No 49, FT-1,
CE low voltage directive 73/23/EEC & 93/68/EEC., IEC 60227-5, ROHS compliant

Cable Construction

- - Bare copper fine wire conductor
- Stranded to DIN VDE 0295 cl. 5, BS 6360 cl. 5, IEC 60228 cl. 5 and HD 383
- PVC core insulation T12 to VDE-0281 Part 1
- Color coded to VDE-0293-308
- Green-yellow grounding (3 conductors and above)
- PVC outer jacket TM2

Technical Characteristics

- Working voltage VDE: 300/500 volts
- Working Voltage UL/CSA: 300 volts
- Test voltage: 2000 volts
- Flexing bending radius: 7.5 x Ø
- Static bending radius: 4 x Ø
- Flexing temperature: -5º C to +70º C
- Static temperature: -40º C to +70º C
- Flame retardant: IEC 60332.1, VW-1
- Insulation resistance: 20 MΩ x km

          

Cable Parameter

AWG
No. of Cores x Nominal Cross Sectional Area # x mm²
Nominal Thickness of Insulation mm
Nominal Thickness of Sheath mm
Nominal Overall Diameter mm
Nominal Copper Weight kg/Km
NominaWeight kg/Km
17(32/32)
2 x 1
0.6
0.8
7.2
19.2
56
17(32/32)
3 x 1
0.6
0.8
7.6
28.8
73
17(32/32)
4 x 1
0.6
0.9
8.6
38.4
86
17(32/32)
5 x 1
0.6
0.9
9.4
48
105
16(30/30)
2 x 1.5
0.7
0.8
7.6
28
82
16(30/30)
3 x 1.5
0.7
0.9
8.3
44
96
16(30/30)
4 x 1.5
0.7
1
9.3
58
117
16(30/30)
5 x 1.5
0.7
1.1
10.4
72
144
14(30/50)
2 x 2.5
0.8
1
9.2
48
118
14(30/50)
3 x 2.5
0.8
1.1
10
72
152
14(30/50)
4 x 2.5
0.8
1.1
10.9
96
192
14(30/50)
5 x 2.5
0.8
1.2
12.2
120
243
12(56/28)
2 x 4
0.8
1.1
10.6
76
195
12(56/28)
3 x 4
0.8
1.2
11.5
115
235
12(56/28)
4 x 4
0.8
1.2
12.4
154
300
12(56/28)
5 x 4
0.8
1.4
14.1
192
361