Home
Chi siamo
Prodotti
Scaricare
Biblioteca tecnica
Contatto
Richiesta
Mappa del sito 
Collegamenti
 

Allarme & Cavo Audio & Elettronico

Cavo di Equivalente di Belden

Cavo coassiale

Cavo di Controllo

Cavo Fibra Ottica

Cavo Flessibile

Cavo strumentazione

Cavi LAN
Cavo Energia
Cavo Ferroviario

Robotic

Cavo per Materiale Rotabile
Cavo di gomma
Cavo di Sicurezza

Cavo Telefonico

Aeroporto Cavi

Bus Cavi

Serracavi

Data Cable

Calore di rilevamento Cavi
Cavi ad alta temperatura
Cavi autostrada
Marine, OIL,GAS & Petrochemical Cables
Cavi Speciali
Cavi a spirale
Termocoppia Cavi
Mining Cables
Industrial Cables
Undersea Cables
Military Cables
Marine Cables
Hoop-Up Wire
Other Cables
     
  indoor tight buffer fiber optic cable  
Indoor Used Tight Buffered Fiber
Optical Cable
outdoor multi loose tube fiber optic cable
Outdoor Used Multi Loose Tube
Fiber Optical Cable
 
  Industrial Cables  

Industrial Cables

H05Z-U/H07Z-U/H07Z-R

Application and Description

These cables are designed for the internal wiring of switchboards and distributor boards with an alternating
nominal voltage up to 1000 Volts or a direct voltage up to 750 volts. Generally install in pipes or ducts and
internal wiring of appliances with maximum operating temperature of 90º C, and generally in areas (such as
public and government buildings) where smoke and toxic fumes may cause a threat to life and equipment.
The cables produce no corrosive gasses when burnt which is particularly important where electronic
equipment is installed.

Standard and Approval

<HAR> HD 22.9 S2, VDE-0282 Part-9, BS 7211, IEC 60754-2, EN 50267, VDE 0482-267, CE Low Voltage
Directive 73/23/EEC and 93/68/EEC, ROHS compliant

Cable Construction

- Solid bare copper single wire to IEC 60228 Cl-1(H05Z-U / H07Z-U)
- Bare copper strands to IEC 60228 Cl-2 (H07Z-R)
- Cross-link polyolefin EI5 core insulation
- Cores to VDE-0293 colors
- LSOH - low smoke, zero halogen

           

Technical Characteristics

- Working voltage: 300/500v (H05Z-U), 450/750v (H07Z-U / H07Z-R)
- Test voltage: 2500 volts
- Flexing bending radius: 15 x Ø
- Static bending radius: 10 x Ø
- Flexing temperature: +5º C to +90º C
- Short circuit temperature: +250º C
- Flame retardant: IEC 60332.1
- Insulation resistance: 10 MΩ x km

Cable Parameter

AWG
No. of Cores x Nominal Cross Sectional Area # x mm²
Nominal Thickness of Insulation mm
Nominal Overall Diameter
mm
Nominal Copper Weight kg/Km
Nominal Weight kg/Km
H05Z-U
20
1 x 0.5
0.6
2.0
4.8
8
1 x 0.75
0.6
2.2
7.2
12
1 x 1
0.6
2.3
9.6
14
H07Z-U
16
1 x 1.5
0.7
2.8
14.4
20
14
1 x 2.5
0.8
3.3
24
30
12
1 x 4
0.8
3.8
38
45
10
1 x 6
0.8
4.3
58
65
8
1 x 10
1.0
5.5
96
105
H07Z-R
16(7/24)
1 x 1.5
0.7
3.0
14.4
21
14(7/22)
1 x 2.5
0.8
3.6
24
33
12(7/20)
1 x 4
0.8
4.1
39
49
10(7/18)
1 x 6
0.8
4.7
58
71
8(7/16)
1 x 10
1
6.0
96
114
6(7/14)
1 x 16
1
6.8
154
172
4(7/12)
1 x 25
1.2
8.4
240
265
2(7/10)
1 x 35
1.2
9.3
336
360
1(19/13)
1 x 50
1.4
10.9
480
487
2/0(19/11)
1 x 70
1.4
12.6
672
683
3/0(19/10)
1 x 95
1.6
14.7
912
946
4/0(37/12)
1 x 120
1.6
16.0
1152
1174
300MCM(37/11)
1 x 150
1.8
17.9
1440
1448
350MCM(37/10)
1 x 185
2.0
20.0
1776
1820
500MCM(61/11)
1 x 240
2.2
22.7
2304
2371