A-2YF(L)2Y n x 2 Outdoor Telecommunication Cable According To DIN VDE 0816 Part 1
Norma di riferimento: A-02Y(L)2Y according to DIN VDE 0816 Part 1
Applicazione: This cable is used in local telephone networks as subscriber cable
Materiale Conduttore: Solid annealed copper conductor
Materiale Isolamento: Solid PE(2Y)
Laying-up: Star quads in unit stranding
Wrapping Polyester Tape
Screen Material: Aluminium Foil with synthetic coating
Materiale guaina : PE
Colore della guaina: Black
Temperature Range: Flexible: -20 ℃ to +50 ℃ fixed installation:- 40℃ to + 70℃
Operating Voltage: 150V to 225V
Performance Elettrica:
Conductor Diameter (mm) |
Insulation Resistance of per km at 20 o C
Min. (GOhms) |
Conductor Resistance per km loop
Max. (Ohms) |
0.40 |
1.5 |
300 |
0.60 |
1.5 |
130 |
0.80 |
1.5 |
73.2 |
Size & Dimensions:
A -2YF(L)2Y ... x 2 x 0,6 STIII BD
Part No. |
No.of pairs |
Outerdiameter
( mm ) |
Cable Weight
( kg/km ) |
Copper Weight
(kg/km) |
CCL-TC-2YF6P0.6 |
6 |
12.0 |
130 |
34 |
CCL-TC-2YF10P0.6 |
10 |
13.5 |
170 |
57 |
CCL-TC-2YF20P0.6 |
20 |
16.0 |
260 |
113 |
CCL-TC-2YF30P0.6 |
30 |
18.0 |
340 |
170 |
CCL-TC-2YF40P0.6 |
40 |
20.0 |
420 |
226 |
CCL-TC-2YF50P0.6 |
50 |
21.5 |
490 |
283 |
CCL-TC-2YF70P0.6 |
70 |
24.5 |
650 |
396 |
CCL-TC-2YF100P0.6 |
100 |
28.0 |
880 |
565 |
CCL-TC-2YF150P0.6 |
150 |
33.0 |
1260 |
848 |
CCL-TC-2YF2006P0.6 |
200 |
37.5 |
1640 |
1131 |
A -2YF(L)2Y ... x 2 x 0.8 STIII BD
Part No. |
No.of pairs |
Outer diameter
( mm ) |
Cable Weight
( kg/km ) |
Copper Weight
(kg/km) |
CCL-TC-2YF6P0.8 |
6 |
13.0 |
160 |
60 |
CCL-TC-2YF10P08 |
10 |
15 |
225 |
101 |
CCL-TC-2YF20P0.8 |
20 |
18.5 |
360 |
201 |
CCL-TC-2YF30P0.8 |
30 |
21.0 |
490 |
302 |
CCL-TC-2YF40P0.8 |
40 |
23.5 |
610 |
402 |
CCL-TC-2YF50P0.8 |
50 |
26.0 |
750 |
503 |
CCL-TC-2YF70P0.8 |
70 |
29.5 |
990 |
704 |
CCL-TC-2YF100P0.8 |
100 |
34.0 |
1350 |
1005 |
CCL-TC-2YF150P0.8 |
150 |
41.0 |
2020 |
1508 |
CCL-TC-2YF2006P0.8 |
200 |
47.0 |
2650 |
2011 |
|