Bus Cables
E-Bus Cables
Application: These cables are used for the transmission of bus signals in buildings, where intelligent system are used. The EIB bus can be used to control lighting, blinds, heating, ventilation,
indicator boards, etc. This cables can maintain perfect communicationaccording to EIB regulations
(European installation bus).
2 Pairs 4 Core FRNC & PVC E-Bus Cables
2 Pairs 4 Core PE E-Bus Cables
4 Pairs 4 Core PVC E-Bus Cables
2 Pairs 4 Core FRNC & PVC E-Bus Cables
Conductor: Bare Copper
Insulation: PVC
Conductor Colour: White, Yellow, Red, Black
Stranding: Star quad
Shielding: Polyester foil over stranded bundle
Total Shielding: Polyester foil, aluminum-lined
Sheath/Jacket: PVC
Colour: Blue, Green
Drain Wire: Yes
Outer Cable Diameter: 6.6 mm ± 0.3 mm
Operating temperature: - 30 °C to +70°C
Standards: EIB Standard
Size (Type) |
Characteristic Impedance |
Conductor Resistance |
Insulation Resistance |
Mutual Capacitance |
Min. Bending Radius |
Caloric Load, approx. value |
Weight |
2 X 2 X 0.8mm2 (Blue) |
100 Ohm |
73.2 Ohm/km |
0.10 GOhm x km Min. |
100.0 nF/km Nom. |
95.0 mm |
0.90 MJ/m |
Approx. 54.0 kg/km |
2 X 2 X 0.8mm2 (Green) |
100 Ohm |
73.2 Ohm/km |
0.10 GOhm x km Min. |
100.0 nF/km Nom. |
95.0 mm |
0.90 MJ/m |
Approx. 54.0 kg/km |
2 Pairs 4 Core PE E-Bus Cables
Conductor: Bare Copper
Insulation: PE
Conductor Colour: White, Yellow, Red, Black
Stranding: Star quad
Shielding: Polyester foil over stranded bundle
Total Shielding: Polyester foil, aluminum-lined
Sheath/Jacket: FRNC
Colour: Blue
Drain Wire: Yes
Outer Cable Diameter: 6.6 mm ± 0.3 mm
Operating temperature: - 30 °C to +70°C
Standards: EIB Standard
Size (Type) |
Characteristic Impedance |
Conductor Resistance |
Insulation Resistance |
Mutual Capacitance |
Min. Bending Radius |
Caloric Load, approx. value |
Weight |
2 X 2 X 0.8mm2 |
100 Ohm |
73.2 Ohm/km |
0.10 GOhm x km Min. |
100.0 nF/km Nom. |
95.0 mm |
0.58 MJ/m |
Approx. 54.0 kg/km |
4 Pairs 4 Core PVC E-Bus Cables
Conductor: Bare Copper
Insulation: PVC
Conductor Colour: White, Yellow, Red, Greed, Blue, Brown, White, White
Stranding: Double Conductor
Shielding: Polyester foil over stranded bundle
Total Shielding: Polyester foil, aluminum-lined
Sheath/Jacket: PVC
Colour: Blue
Drain Wire: Yes
Outer Cable Diameter: 8.3 mm ± 0.4 mm
Operating temperature: - 30 °C to +70°C
Standards: EIB Standard
Size (Type) |
Characteristic Impedance |
Conductor Resistance |
Insulation Resistance |
Mutual Capacitance |
Min. Bending Radius |
Caloric Load, approx. value |
Weight |
4 X 2 X 0.8mm2 |
100 Ohm |
73.2 Ohm/km |
0.10 GOhm x km Min. |
100.0 nF/km Nom. |
120.0 mm |
1.37 MJ/m |
Approx. 92.0 kg/km |
|