Home
Over ons
Produkten
Downloaden
Technische Lib
Contact
Navraag
Sitemap
Links
 

Alarm & Audio & Elektronische Kabel

Belden gelijkwaardige kabels

Coax Kabels

Control Kabels

Fiber Optic Kabels

Flexibele Kabels

Instrumentatie Kabel

Lan kabels
Energie Kabel
Spoorweg Kabel

Robotica

Rollend materieel kabels
Rubber & Crane kabels
Beveiliging kabels

Telefoonkabels

Luchthaven Kabels

Bus kabels

Kabel Klieren

Data Kabels

Hitte detectie kabels
Hoge temperatuur kabels
Kabels snelweg
Marine, olie-, gas-en petrochemische Kabels
Speciaal Kabels
Spiraal Kabels
Thermokoppel Kabels
Mining Cables
Industrial Cables
Undersea Cables
Military Cables
Marine Cables
Hoop-Up Wire
Other Cables
     
  Indoor tight buffer fiber optic cable  
Indoor Used Tight Buffered Fiber
Optical Cable
outdoor multi loose tube fiber optic cable
Outdoor Used Multi Loose Tube
Fiber Optical Cable
 
  Instrumentatie Kabels 

BS 6231 Instrumentatie Kabels

Aanvraag :
These cables are suitable for internal wiring of appliances and switch, control, metering and instrument panels of switchgear, etc

Bouw
Normen : BS 6231, UL 83, CSA C22.2, UL Flame test UL 1581/VW1 FT1 FT2
Dirigent : plain annealed
Isolatie : Flexible PVC
Temperatuurbereik: 0 o C -105 o C
Voltage rating : 0.6 / 1kV
Min. Bending radius : 3 x Overall diameter
Insulation colours : 0.5mm² to 25 mm² Red, black, white, grey, brown, orange, yellow, blue, green, and green/yellow.
35mm² to 120 mm² Red, black and green/yellow. . Other colours available on request.

Relevant Standards :
To BS6231, UL Style 1015, 1028, 1283, 1284; CSA TEW 105 °C; UL VW -1 Vertical Flame Test

Current Ratings
The table below lists the full Thermal current ratings which will raise the Conductor temperature to 85 °C when one cable is installed in free air at an Ambient temperature of 45 °C.
These ratings are applicable for installations which ensure that the operation of the protective device is not greater than 1.45 times the continuous current carrying capacity of the cable.
Where protection is by means of semi-enclosed fuses to BS 3036 the rating must be multiplied by a factor of 0.76.

Note:Sizes 150.0mm², 185.0mm² and 240.0mm², 300.0mm² & 400mm² are classed as dual Rated and are manufactured to UL & BS 6231 only.

SIZE
mm²

Weerstand per 1000m van 20 ° C
OHM

Stroombereik
AMP

Benaderende volt constante daling
MV/A/M

0.5

39

11

46

0.75

26

14

31

1

19.5

17

22

1.5

13.3

21

15

2.5

7.98

30

9.1

4

4.95

41

5.7

6

3.3

53

3.8

10

1.91

75

2.2

16

1.21

100

1.4

25

0.78

136

0.89

35

0.554

167

0.64

50

0.386

204

0.45

70

0.272

259

0.32

95

0.206

321

0.24

120

0.161

374

0.19

150

0.129

429

0.15

185

0.106

496

0.13

240

0.0801

595

0.092

300

0.0641

680

0.073

400

0.06

868

@70 C 0.145

The voltage drop figures are for one cable only. For other circuit arrangements they should be adjusted as follows:

Single-phase 50Hz ac or 2-wire dc circuit's

x2

Three-phase 50Hz ac circuit's

x1.732

BS 6231 Instrumentation Cables

Range & Dimensions for BS 6231 Instrumentation cables

PART NO.

SIZE
mm²

STRANDING
mm

SIZE
AWG

UL STYLE
NUMBER

NOMINALE ISOLATIE
mm

Totale nominale diameter
mm

GEWICHT
kg/km

CCL-IC-BS6231-0.50SQ

0.5

16/0.20

22

1015

0.8

2.6

12

CCL-IC-BS6231-0.75SQ

0.75

24/0.20

20

1015

0.8

2.8

15

CCL-IC-BS6231-1.00SQ

1

32/0.20

18

1015

0.8

3

18

CCL-IC-BS6231-1.50SQ

1.5

30/0.25

16

1015

0.9

3.3

23

CCL-IC-BS6231-2.50SQ

2.5

50/0.25

14

1015

1.0

3.7

34

CCL-IC-BS6231-4.00SQ

4

56/0.30

12

1015

1.0

4.4

50

CCL-IC-BS6231-6.00SQ

6

84/0.30

10

1015

1.3

5.1

71

CCL-IC-BS6231-10.0SQ

10

80/0.40

8

1028

1.5

6.9

123

CCL-IC-BS6231-16.0SQ

16

126/0.40

6

1283

1.5

8.6

209

CCL-IC-BS6231-25.0SQ

25

196/0.40

4

1283

1.6

10.5

296

CCL-IC-BS6231-35.0SQ

35

276/0.40

2

1283

2.0

11.9

400

CCL-IC-BS6231-50.0SQ

50

396/0.40

1

1284

2.0

14.4

582

CCL-IC-BS6231-70.0SQ

70

360/0.50

2/0

1284

2.0

16.7

796

CCL-IC-BS6231-95.0SQ

95

475/0.50

3/0

1284

2.3

19

1025

CCL-IC-BS6231-120SQ

120

608/0.50

4/0

1284

2.4

20.5

1282

CCL-IC-BS6231-150SQ

150

756/0.50

MCM300

104

2.4

23.14

1627

CCL-IC-BS6231-185SQ

185

925/0.50

MCM350

104

2.4

25.4

1959

CCL-IC-BS6231-240SQ

240

1221/0.50

MCM500

104

2.8

28.66

2254

CCL-IC-BS6231-300SQ

300

1525/0.50

MCM600

1015

-

31.5

3157

CCL-IC-BS6231-400SQ

400

2013/0.50

MCM800

1284

-

36

4051