RSE/STD/024 Part 6 Rolling Stock Cable300/500V Multipair RSE/STD/024 Part 6 Rolling Stock Type Ⅷ screened Cable, with jacket
Cross- sectional Area:0.5mm2-1.0mm2
Voltage rating:30/50V
Conductor:Flexible Stranded Tinned Copper
Number of pairs:1,2,3
Conductor class:IEC 60228 Class 5
Screen:Copper Braid Screen
Insulation:Cross linked EPR rubber type EI 107, Standard wale
Jacket:Cross linked EVA rubber type EM 104
Fire standard:IEC 332-3C,IEC754;IEC1034-1/2
No. of Pairs | Cross Sectional Area mm2 | Number and Nominal Diameter of Strands mm |
Voltage Rating V | Nominal Overall mm |
Nominal Weight kg/km |
1 Pair | 0.5 | 16/0.2 | 30/50 | 8.45 | 99.0 |
1 Pair | 0.75 | 24/0.2 | 30/50 | 9.2 | 110.0 |
1 Pair | 1.0 | 32/0.2 | 30/50 | 9.5 | 139.0 |
1 Pair | 1.0 | 32/0.2 | 30/50 | 11.7 | 186.0 |
1 Pair | 1.0 | 32/0.2 | 30/50 | 15.6 | 306.0 |
2 Pair | 1.0 | 32/0.2 | 30/50 | 15.7 | 443.0 |
3 Pair | 1.0 | 32/0.2 | 30/50 | 21.7 | 662.0 |
300/500V Multipair RSE/STD/024 Part 6 Rolling StockType Ⅸ screened Cable, with jacket
Cross- sectional Area:0.5mm2-1.0mm2
Voltage rating:300/500V
Conductor:Flexible Stranded Tinned Copper
Number of pairs:1,2,3,4
Conductor class:19/37 AWG Stranding
Insulation:Cross linked EPR rubber type EI 107, Reduced Wall
Screen:Copper Braid Screen
Jacket:Cross linked EVA rubber type EM 104
Fire standard:IEC 332-3C,IEC754;IEC1034-1/2
No. of Pairs | Cross Sectional Area mm2 | Number and Nominal Diameter of Strands mm | Voltage Rating V | Nominal Overall mm |
Nominal Weight kg/km |
1 Pair | 0.5 | 19/0.18 | 30/50 | 6.1 | 57.0 |
2 Pair | 0.5 | 19/0.18 | 30/50 | 10.2 | 110.0 |
1 Pair | 1.0 | 37/0.18 | 30/50 | 7.0 | 85.0 |
2 Pair | 1.0 | 37/0.18 | 30/50 | 12.2 | 187.5 |
3 Pair | 1.0 | 37/0.18 | 30/50 | 12.9 | 217.0 |
4 Pair | 1.0 | 37/0.18 | 30/50 | 14.0 | 290.0 |
600/1000V Singlecore RSE/STD/024 Part 6 Rolling Stock TypeⅠCable, unsheathed
Cross-sectional Area:0.5mm2-4mm2
Voltage rating:600/1000V
Conductor:Flexible Stranded Tinned Copper
Number of cores:1
Conductor class:19/37 AWG Stranding
Insulation:Cross linked EPR rubber type EI 107 Reduced wall
Fire standard:IEC 332-3C,IEC754;IEC1034-1/2
No. of Cores | Cross Sectional Area mm2 | Number and Nominal Diameter of Strands mm |
Voltage Rating V | Nominal Overall mm |
Nominal Weight kg/km |
single core | 0.5 | 19/0.18 | 600/1000 | 1.5 | 5.9 |
single core | 0.75 | 37/0.16 | 600/1000 | 1.76 | 8.7 |
single core | 1.0 | 37/0.18 | 600/1000 | 1.9 | 10.7 |
single core | 1.5 | 37/0.23 | 600/1000 | 2.25 | 16.5 |
single core | 2.5 | 37/0.3 | 600/1000 | 2.84 | 28.0 |
single core | 4.0 | 37/0.37 | 600/1000 | 3.44 | 42.0 |
600/1000V Singlecore RSE/STD/024 Part 6 Rolling StockType Ⅱ Cable, unsheathed
Cross- sectional Area :0.75mm2-300mm2
Voltage rating :600/1000V
Conductor:Flexible Stranded Tinned Copper
Number of cores :1
Conductor class :IEC 60228 Class 5
Insulation:Cross linked EPR rubber type EI 107, Standard Wall
Fire standard:IEC 332-3C,IEC754;IEC1034-1/2
No. of Cores/Pairs | Cross Sectional Area mm2 |
Number and Nominal Diameter of Strands mm |
Voltage Rating V |
Nominal Overall Diameter mm |
Nominal Weight kg/km |
singlecore | 0.75 | 24/0.2 | 600/1000 | 2.99 | 14.9 |
singlecore | 1.0 | 32/0.2 | 600/1000 | 3.3 | 19.2 |
singlecore | 1.5 | 30/0.25 | 600/1000 | 3.69 | 26.3 |
singlecore | 2.5 | 50/0.25 | 600/1000 | 4.16 | 37.8 |
singlecore | 4.0 | 56/0.3 | 600/1000 | 4.95 | 56.6 |
singlecore | 6.0 | 84/0.3 | 600/1000 | 5.55 | 80.4 |
singlecore | 10.0 | 80/0.4 | 600/1000 | 7.0 | 135.0 |
singlecore | 16.0 | 128.4 | 600/1000 | 8.35 | 201.8 |
singlecore | 25.0 | 196/0.4 | 600/1000 | 10.2 | 3.9.3 |
singlecore | 35.0 | 2/6/0.4 | 600/1000 | 11.75 | 404.1 |
singlecore | 50.0 | 396/0.4 | 600/1000 | 13.7 | 562.0 |
singlecore | 70.0 | 360/0.5 | 600/1000 | 16.25 | 768.0 |
singlecore | 95.0 | 476/0.6 | 600/1000 | 18.05 | 1002.8 |
singlecore | 150.0 | 756/0.5 | 600/1000 | 22.95 | 1583.0 |
singlecore | 240.0 | 1221/0.5 | 600/1000 | 27.9 | 2516.0 |