Bus Cables
CAN Bus Cables
Application: These cables is a variable field bus system. Automation Industries, such as the textile or construction machine industry are commonly use this type of cables.
CAN Bus 0.22mm2 Flexible Cables
CAN Bus 0.34mm2 Flexible Cables
CAN Bus 0.50mm2 Flexible Cables
CAN Bus 0.25mm2 Drag Chain Cables
CAN Bus 0.22mm2 Flexible Cables
Conductor: Bare Copper (AWG 24/7)
Insulation: Cell PE
Conductor Colour: White, Brown / White, Brown, Green-Yellow
Stranding: Double Conductor (1 pair 2 core) / Star quad (4 pair single core)
Shielding: Polyester foil over stranded bundle
Total Shielding: Tinned Copper Braid
Sheath/Jacket: PVC
Colour: Violet
Outer Cable Diameter: 5.4 mm ± 0.2 mm (1 pair 2 core) / 6.9 mm ± 0.2 mm
Nominal Voltage: 30 V
Test Voltage: 1.5 kV
Operating temperature: - 40 °C to +70°C
Standards: Profibus acc. to DIN 19245 T3 and EN 50170
UL Style: UL Style 2571
Size (Type) |
Characteristic Impedance |
Conductor Resistance |
Insulation Resistance |
Mutual Capacitance |
Min. Bending Radius |
Caloric Load, approx. value |
Weight |
1 X 2 X 0.22mm2 |
120 Ohm ± 10% |
87.0 Ohm/km |
1.0 GOhm x km Min. |
58.0 nF/km Nom. |
81.0 mm |
0.57 MJ/m |
Approx. 35.0 kg/km |
4 X 1 X 0.22mm2 |
120 Ohm ± 10% |
87.0 Ohm/km |
1.0 GOhm x km Min. |
58.0 nF/km Nom. |
107.0 mm |
1.23 MJ/m |
Approx. 60.0 kg/km |
CAN Bus 0.34mm2 Flexible Cables
Conductor: Bare Copper (AWG 24/7)
Insulation: Cell PE
Conductor Colour: White, Brown / White, Brown, Green-Yellow
Stranding: Double Conductor (1 pair 2 core) / Star quad (4 pair single core)
Shielding: Polyester foil over stranded bundle
Total Shielding: Tinned Copper Braid
Sheath/Jacket: PVC
Colour: Violet
Outer Cable Diameter: 6.5 mm ± 0.2 mm (1 pair 2 core) / 8.0 mm ± 0.2 mm
Nominal Voltage: 30 V
Test Voltage: 2.0 kV
Operating temperature: - 25 °C to +70°C
Standards: Profibus acc. to DIN 19245 T3 and EN 50170
UL Style: UL Style 2571
Size (Type) |
Characteristic Impedance |
Conductor Resistance |
Insulation Resistance |
Mutual Capacitance |
Min. Bending Radius |
Caloric Load, approx. value |
Weight |
1 X 2 X 0.34mm2 |
120 Ohm ± 10% |
57.5 Ohm/km |
5.0 GOhm x km Min. |
40.0 nF/km Nom. |
98.0 mm |
1.11 MJ/m |
Approx. 54.0 kg/km |
4 X 1 X 0.34mm2 |
120 Ohm ± 10% |
57.5 Ohm/km |
5.0 GOhm x km Min. |
40.0 nF/km Nom. |
120.0 mm |
1.18 MJ/m |
Approx. 77.0 kg/km |
CAN Bus 0.50mm2 Flexible Cables
Conductor: Bare Copper (AWG 20/7)
Insulation: Foam skin PE
Conductor Colour: White, Brown / White, Brown, Green-Yellow
Stranding: Double Conductor (1 pair 2 core) / Star quad (4 pair single core)
Shielding: Polyester foil over stranded bundle
Total Shielding: Tinned Copper Braid
Sheath/Jacket: PVC
Colour: Violet
Outer Cable Diameter: 7.0 mm ± 0.2 mm (1 pair 2 core) / 8.5 mm ± 0.2 mm
Test Voltage: 1.5 kV
Operating temperature: - 40 °C to +70°C
Standards: Profibus acc. to DIN 19245 T3 and EN 50170
UL Style: UL Style 2571
Size (Type) |
Characteristic Impedance |
Conductor Resistance |
Insulation Resistance |
Mutual Capacitance |
Min. Bending Radius |
Caloric Load, approx. value |
Weight |
1 X 2 X 0.50mm2 |
120 Ohm ± 10% |
37.0 Ohm/km |
1.0 GOhm x km Min. |
50.0 nF/km Nom. |
105.0 mm |
1.09 MJ/m |
Approx. 69.0 kg/km |
4 X 1 X 0.50mm2 |
120 Ohm ± 10% |
37.0 Ohm/km |
1.0 GOhm x km Min. |
50.0 nF/km Nom. |
128.0 mm |
1.64 MJ/m |
Approx. 100.0 kg/km |
CAN Bus 0.25mm2 Drag Chain Cable
Conductor: Bare Copper (AWG 24/19)
Insulation: PE
Conductor Colour: White, Brown / White, Brown, Green-Yellow
Stranding: Double Conductor (1 pair 2 core) / Star quad (4 pair single core)
Shielding: Polyester foil over stranded bundle
Total Shielding: Tinned Copper Braid
Sheath/Jacket: PUR
Colour: Violet
Outer Cable Diameter: 6.2 mm ± 0.3 mm (1 pair 2 core) / 6.5 mm ± 0.3 mm
Test Voltage: 1.5 kV
Operating temperature: - 20°C to +70°C
Standards: Profibus acc. to DIN 19245 T3 and EN 50170
Size (Type) |
Characteristic Impedance |
Conductor Resistance |
Insulation Resistance |
Mutual Capacitance |
Min. Bending Radius |
Caloric Load, approx. value |
Weight |
1 X 2 X 0.25mm2 |
120 Ohm ± 10% |
85.0 Ohm/km |
1.0 GOhm x km Min. |
50.0 nF/km Nom. |
90.0 mm |
0.80 MJ/m |
Approx. 40.0 kg/km |
4 X 1 X 0.25mm2 |
120 Ohm ± 10% |
85.0 Ohm/km |
1.0 GOhm x km Min. |
50.0 nF/km Nom. |
95.0 mm |
0.94 MJ/m |
Approx. 45.0 kg/km |
|