Caoutchouc et Câble Crâne |
|
|
|
Caoutchouc et Câble Crâne
EPR/CSP 0361 TQ H0FR Welding Cable Single Core EPR Insulated CSP sheathed to BS 638 Part4 85 Deg 100V
CONSTRUCTION : Electrical Characteristics
Chef d'orchestre: Extra Flexible Class6 Tinned/Plain Copper to BS6360. Flexible Class 5 for 120 mm sq and above
Séparateur: Crepe Paper /PETP Tape
Isolation: Ethylene Propylene Rubber (E.P.R.) to BS 7655
Gaine: Chlorosulphonated Polythylene (C.S.P.) H.O.F.R. ( Heat and Fire Retardant ) to BS 7655
Couleur gaine: Orange ( Tinned conductors ) Black ( Plain conductors )
Flexible aluminium conductors available upon request.
APPLICATION :
This range of Cables are designed as highly flexible voltage leads, primarily for the secondary (high current) connection to automatic or hand held metal arc welding electrodes.
May also be used for non welding applications such as earthing return leads, flexible tails on power supply. Busbar connections.
TECHNICAL DATA :
Tension: 100V (If used in an environment where they are not liable to sustain mechanical damage these Cables may be used at 450/700V in the control panels, switchgears etc.
Evaluation de température: -20 to +85°C
Rayon de courbure: 6 x Overall Diameter
RATING FACTORS :
The current ratings given are based on an ambient temperature of 25 Deg.
Rating factors for higher temperatures are: Ambient Temp: 30 Deg 35 Deg 40 Deg 45 Deg
Rating Factor: 0.96 0.91 0.87 0.82
Where total cable lengths in excess of 15m are involved, it may be necessary to use cable of larger cross section to ensure that the voltage drop is not excessive and welding currents are maintained at adequate levels. |
DUTY CYCLE :
The duty cycle is defined as the time for which the current flows expressed as a percentage of the complete cycle, which is taken as 5 minutes. Since the length of time for which current flows during a welding operation varies, occasional to continuous, the duty cycle can vary from as little as 20% to a maximum of 100% on automatic operation. |
Automatic Welding up to 100%.
Semi Automatic Welding 30-85%.
Manual Welding 30-60%.
Intermittent or Occasional Welding up to 20%.
Taille
MM |
Echouage classe |
Echouage
MM |
Epaisseur de la gaine mm |
Nominal
O/Dia MM |
Poids
Kg / Km |
Max
Duty Cycle
100% |
Max
Duty
Cycle
60% |
Max
Duty
Cycle
30% |
16 |
6 |
513 / 0.20 |
2.0 |
10.9 |
212 |
135 |
175 |
245 |
25 |
6 |
783 / 0.20 |
2.0 |
12.5 |
300 |
180 |
230 |
330 |
35 |
6 |
1107 / 0.20 |
2.0 |
14 |
403 |
225 |
290 |
410 |
50 |
6 |
1566 / 0.20 |
2.2 |
16 |
560 |
285 |
370 |
520 |
70 |
6 |
2214 / 0.20 |
2.4 |
18.6 |
776 |
355 |
460 |
650 |
95 |
6 |
2997 / 0.20 |
2.6 |
21.2 |
1035 |
430 |
560 |
790 |
120 |
5 |
608 / 0.50 |
2.8 |
23.1 |
1300 |
500 |
650 |
910 |
185 |
5 |
925/0.50 |
3.2 |
29.0 |
2050 |
660 |
850 |
1200 |
Electrical Characteristics |
Loading Current Values (amperes)
Nominal Cross Sectional Area mm2 |
Loading Current in Amps for the Following Duty Cycles |
mm2 |
100% |
85% |
60% |
30% |
16 |
135 |
145 |
175 |
245 |
25 |
180 |
195 |
230 |
330 |
35 |
225 |
245 |
290 |
410 |
50 |
285 |
310 |
370 |
520 |
70 |
355 |
385 |
460 |
650 |
95 |
430 |
470 |
560 |
790 |
120 |
500 |
540 |
650 |
910 |
185 |
660 |
715 |
850 |
1200 |
Correction Factors
Cable operating temperature also varies according to the prevailing ambient temperature. These cables are designed to give optimum performance up to an operating temperature of 85°C at an ambient temperature of 25°C.
The reduction factors for increased ambient temperature are: |
Température ambiante |
30°C |
35°C |
40°C |
45°C |
50°C |
55°C |
Facteur de correction |
0.96 |
0.91 |
0.87 |
0.82 |
0.76 |
0.79 |
Conductor Resistance (ohms per kilometre) and Voltage Drop
Nominal Cross Sectional Area |
Une résistance maximale à 20 ° C étamé |
Chute de tension (For Guidance Only) |
Volts Per 100 Amp Per 10 Metres
DC Current * |
20°C |
60°C |
85°C |
mm2 |
ohms/Km |
V |
V |
V |
16 |
1.240 |
1.240 |
1.430 |
1.560 |
25 |
0.795 |
0.795 |
0.920 |
0.998 |
35 |
0.565 |
0.565 |
0.654 |
0.709 |
50 |
0.393 |
0.393 |
0.455 |
0.493 |
70 |
0.277 |
0.277 |
0.321 |
0.348 |
95 |
0.210 |
0.210 |
0.246 |
0.264 |
120 |
0.164 |
0.164 |
0.190 |
0.206 |
185 |
0.108 |
0.108 |
0.125 |
0.136 |
*Note: |
The values for AC Current may be much higher, depending on the configuration of the cables. |
|