Gummi u. Kran-Kabel
Coil End Lead to BS6195 Type 4
BAU:
Dirigent: Flexible Tinned Copper to BS6360
Isolierung: Ethylene Propylene Rubber E.P.R ; Type FR1 (Voltage Categories A & C) & Type FR2 (Voltage Categories D & E) to BS 7655.
Mantel: Chlorosulphonated Polyethylene C.S.P. HOFR Black. To BS 6899
ANWENDUNG :
This range of Cables is designed as power leads for permanent connecton to coil winding motors, panel wiring and electrical machinery. They are able to withstand high temperature and immersion in varnish. Other applications include vehicle wiring. T he HOFR sheath resists oil and varnish and the stranding is designed as a compromise between flexibility and positional stability. Also suitable as an alternative to tri-rated and bi-rated cable in certain applications
TECHNISCHE DATEN:
Spannung Kategorien
A 300/500V
C 600/1000V
D 1900/3300V
E 3800/6600V
F 6350/11000V
Temperaturbereich im Betrieb: -20oC to +70oC
Biegeradius: Up to 25mm2 = 6 x overall diameter
Above 25mm2 = 8 x overall diameter
SHEATH FARBE :
0.5-10mm2: Red-Black
10mm2 above: Black only.
Einschlägigen Normen:
Cable in accordance with BS6195
Insulation & Sheath to BS6899
OPTIONS
Coiled end lead is also manufactured to BS6899 Type 5 - Silicon insulation 180oC Operating Temperature.
Spannung Kategorie |
Maximale Ausrüstung Prüfspannung (ACrms) |
Nennspannung Bewertung von Kabel Uo/U |
A |
2.5 |
300/500V |
C |
4.0 |
600/1000V |
D |
9.5 |
1900/3300V |
E |
17 |
3800/6600V |
Core und Größe
mm sq |
Strandung(Anzahl der Strand/Strand Durchmesser |
Nenndicke der Isolierung mm |
Insgesamt Nenn-Durchmesser mm Spannung für jede Kategorie |
Spannung Kategorie |
Spannung Kategorie |
A |
C |
D |
E |
A |
C |
D |
E |
Mm |
mm |
|
|
|
|
|
|
|
|
0.5 |
16/0.2 |
0.8 |
1.4 |
- |
- |
3.3 |
4.5 |
- |
- |
0.75 |
24/0.2 |
0.8 |
1.4 |
- |
- |
3.5 |
4.7 |
- |
- |
1.0 |
32/0.2 |
0.8 |
1.4 |
- |
- |
3.7 |
4.9 |
- |
- |
1.5 |
30/0.25 |
0.8 |
1.4 |
- |
- |
4.0 |
5.2 |
- |
- |
2.5 |
50/0.25 |
0.9 |
1.4 |
2.8 |
- |
4.6 |
5.6 |
8.5 |
- |
4.0 |
56/0.3 |
1.0 |
1.4 |
2.8 |
- |
5.4 |
6.3 |
9.1 |
- |
6.0 |
84/0.3 |
1.0 |
1.5 |
2.8 |
- |
6.5 |
7.5 |
10.3 |
- |
10 |
80/0.4 |
1.2 |
1.5 |
2.8 |
- |
7.9 |
8.5 |
11.3 |
- |
16 |
126/0.4 |
- |
1.5 |
2.8 |
5.0 |
- |
9.6 |
12.4 |
17.2 |
25 |
196/0.4 |
- |
1.6 |
2.8 |
5.0 |
- |
11.4 |
13.8 |
18.6 |
35 |
276/0.4 |
- |
1.6 |
2.8 |
5.0 |
- |
12.8 |
12.5 |
20.0 |
50 |
396/0.4 |
- |
1.7 |
2.8 |
5.0 |
- |
14.8 |
17.1 |
22.1 |
70 |
360/0.5 |
- |
1.8 |
2.8 |
5.0 |
- |
17.2 |
19.2 |
24.2 |
95 |
475/0.5 |
- |
2.0 |
3.0 |
5.0 |
- |
19.2 |
22.0 |
26.3 |
120 |
608/0.5 |
- |
2.2 |
3.0 |
5.0 |
- |
21.9 |
23.5 |
27.8 |
150 |
756/0.5 |
- |
2.3 |
3.0 |
5.0 |
- |
24.1 |
25.5 |
29.8 |
185 |
925/0.5 |
- |
2.4 |
3.0 |
5.0 |
- |
26.3 |
27.5 |
32.1 |
240 |
1221/0.5 |
- |
2.4 |
3.0 |
5.0 |
- |
28.3 |
30.6 |
35.1 |
300 |
1525/0.5 |
- |
2.6 |
3.0 |
- |
- |
33.0 |
33.8 |
- |
400 |
2013/0.5 |
- |
2.8 |
3.0 |
- |
- |
37.4 |
37.8 |
- |
630 |
2106/0.6 |
- |
- |
3.2 |
- |
- |
- |
43.5 |
- |
Correction Factors
For ambient air temperatures other than 40°C, the following factors should be applied:
Ambient Air Temp |
Correction Factor |
1.140 |
1.100 |
1.050 |
1.000 |
0.945 |
0.900 |
0.835 |
0.775 |
0.705 |
0.603 |
0.545 |
0.445 |
Where cables are to be grouped in free air, the following factors should be applied:
No. of Cables in Group |
2 |
3 |
4 |
5 |
6 |
7 |
8 |
Correction Factor |
0.80 |
0.70 |
0.70 |
0.60 |
0.56 |
0.50 |
0.50 |
Ambient air temperature 40°C
Conductor operating temperature 90°C
Elektrische Eigenschaften |
Resistance Values (ohms per kilometre)
Nominal Dirigent Bereich |
Nominal Dirigent Strandung |
Max. DC-Widerstand at 20°C |
Max. Dauerstrom Bewertungen
(BS6195) Types |
mm2 |
#/mm |
ohms/Km |
Amp |
0.50 |
16/0.20 |
38.2000 |
13 |
0.75 |
24/0.20 |
25.4000 |
17 |
1.00 |
32/0.20 |
19.1000 |
20 |
1.50 |
30/0.25 |
13.0000 |
26 |
2.50 |
50/0.25 |
7.8200 |
36 |
4.00 |
56/0.30 |
4.8500 |
49 |
6.00 |
84/0.30 |
3.2300 |
64 |
10.00 |
80/0.40 |
1.8500 |
90 |
16.00 |
126/0.40 |
1.1800 |
120 |
25.00 |
196/0.40 |
0.7570 |
163 |
35.00 |
276/0.40 |
0.5380 |
203 |
50.00 |
396/0.40 |
0.3750 |
267 |
70.00 |
360/0.50 |
0.2640 |
324 |
95.00 |
475/0.50 |
0.2000 |
391 |
120.00 |
608/0.50 |
0.1560 |
455 |
150.00 |
756/0.50 |
0.1260 |
525 |
185.00 |
925/0.50 |
0.1030 |
600 |
240.00 |
1121/0.50 |
0.0778 |
725 |
300.00 |
1525/0.50 |
0.0623 |
840 |
400.00 |
2013/0.50 |
0.0472 |
1010 |
630.00 |
2160/0.60 |
0.0292 |
1450 |
Nominal Dirigent Bereich |
Nominal Dirigent Strandung |
Max. DC-Widerstand at 20°C |
Max. Dauerstrom Bewertungen
(BS6195) Types |
mm2 |
#/mm |
ohms/Km |
Amp |
0.50 |
16/0.20 |
38.2000 |
13 |
0.75 |
24/0.20 |
25.4000 |
17 |
1.00 |
32/0.20 |
19.1000 |
20 |
1.50 |
30/0.25 |
13.0000 |
26 |
2.50 |
50/0.25 |
7.8200 |
36 |
4.00 |
56/0.30 |
4.8500 |
49 |
6.00 |
84/0.30 |
3.2300 |
64 |
10.00 |
80/0.40 |
1.8500 |
90 |
16.00 |
126/0.40 |
1.1800 |
120 |
25.00 |
196/0.40 |
0.7570 |
163 |
35.00 |
276/0.40 |
0.5380 |
203 |
50.00 |
396/0.40 |
0.3750 |
267 |
70.00 |
360/0.50 |
0.2640 |
324 |
95.00 |
475/0.50 |
0.2000 |
391 |
120.00 |
608/0.50 |
0.1560 |
455 |
150.00 |
756/0.50 |
0.1260 |
525 |
185.00 |
925/0.50 |
0.1030 |
600 |
240.00 |
1121/0.50 |
0.0778 |
725 |
300.00 |
1525/0.50 |
0.0623 |
840 |
400.00 |
2013/0.50 |
0.0472 |
1010 |
630.00 |
2160/0.60 |
0.0292 |
1450 |
|