LWL Kabel

Flexible Kabel

Instrumentation Kabel

Lan Kabel
EnergieKabel
Bahn-Kabel

Robotik

Rolling Stock Kabel
Gummi u. Kran Kabel
Sicherheit Kabel

Telefon Kabel

Flughafen Kabel

Bus-Kabel

Kabelverschraubungen

Daten Kabel

Heat Detection Kabel
Hochtemperatur-Kabel
Highway Kabel
Marine, Öl, Gas & Petrochemie-Kabel
Special Cables
Spiralkabel
Thermoelement-Kabel
Other Cable
     
  Indoor tight buffer fiber optic cable  
Indoor Used Tight Buffered Fiber
Optical Cable
outdoor multi loose tube fiber optic cable
Outdoor Used Multi Loose Tube
Fiber Optical Cable
 
  Gummi u. Kran-Kabel

Gummi u. Kran-Kabel

Coil End Lead to BS6195 Type 4   

Optionen  

Elektrische Eigenschaften

BAU:
Dirigent: Flexible Tinned Copper to BS6360
Isolierung: Ethylene Propylene Rubber E.P.R ; Type FR1 (Voltage Categories A & C) & Type FR2 (Voltage Categories D & E) to BS 7655.
Mantel: Chlorosulphonated Polyethylene C.S.P. HOFR Black. To BS 6899
ANWENDUNG :
This range of Cables is designed as power leads for permanent connecton to coil winding motors, panel wiring and electrical machinery. They are able to withstand high temperature and immersion in varnish. Other applications include vehicle wiring. T he HOFR sheath resists oil and varnish and the stranding is designed as a compromise between flexibility and positional stability. Also suitable as an alternative to tri-rated and bi-rated cable in certain applications
TECHNISCHE DATEN:
Spannung Kategorien
A 300/500V
C 600/1000V
D 1900/3300V                                   
E 3800/6600V  
F 6350/11000V
Temperaturbereich im Betrieb: -20oC to +70oC
Biegeradius: Up to 25mm2 = 6 x overall diameter
Above 25mm2 = 8 x overall diameter
SHEATH FARBE :
0.5-10mm2: Red-Black
10mm2 above: Black only.
Einschlägigen Normen:
Cable in accordance with BS6195
Insulation & Sheath to BS6899

OPTIONS
Coiled end lead is also manufactured to BS6899 Type 5 - Silicon insulation 180oC Operating Temperature.

Spannung Kategorie

Maximale Ausrüstung Prüfspannung (ACrms)

Nennspannung Bewertung von Kabel Uo/U

A

2.5

300/500V

C

4.0

600/1000V

D

9.5

1900/3300V

E

17

3800/6600V

 

Core und Größe

mm sq

Strandung(Anzahl der Strand/Strand Durchmesser

Nenndicke der Isolierung mm

Insgesamt Nenn-Durchmesser mm Spannung für jede Kategorie

Spannung Kategorie

Spannung Kategorie

A

C

D

E

A

C

D

E

Mm

mm

 

 

 

 

 

 

 

 

0.5

16/0.2

0.8

1.4

-

-

3.3

4.5

-

-

0.75

24/0.2

0.8

1.4

-

-

3.5

4.7

-

-

1.0

32/0.2

0.8

1.4

-

-

3.7

4.9

-

-

1.5

30/0.25

0.8

1.4

-

-

4.0

5.2

-

-

2.5

50/0.25

0.9

1.4

2.8

-

4.6

5.6

8.5

-

4.0

56/0.3

1.0

1.4

2.8

-

5.4

6.3

9.1

-

6.0

84/0.3

1.0

1.5

2.8

-

6.5

7.5

10.3

-

10

80/0.4

1.2

1.5

2.8

-

7.9

8.5

11.3

-

16

126/0.4

-

1.5

2.8

5.0

-

9.6

12.4

17.2

25

196/0.4

-

1.6

2.8

5.0

-

11.4

13.8

18.6

35

276/0.4

-

1.6

2.8

5.0

-

12.8

12.5

20.0

50

396/0.4

-

1.7

2.8

5.0

-

14.8

17.1

22.1

70

360/0.5

-

1.8

2.8

5.0

-

17.2

19.2

24.2

95

475/0.5

-

2.0

3.0

5.0

-

19.2

22.0

26.3

120

608/0.5

-

2.2

3.0

5.0

-

21.9

23.5

27.8

150

756/0.5

-

2.3

3.0

5.0

-

24.1

25.5

29.8

185

925/0.5

-

2.4

3.0

5.0

-

26.3

27.5

32.1

240

1221/0.5

-

2.4

3.0

5.0

-

28.3

30.6

35.1

300

1525/0.5

-

2.6

3.0

-

-

33.0

33.8

-

400

2013/0.5

-

2.8

3.0

-

-

37.4

37.8

-

630

2106/0.6

-

-

3.2

-

-

-

43.5

-

Correction Factors
For ambient air temperatures other than 40°C, the following factors should be applied:

Ambient Air Temp

Correction Factor

1.140

1.100

1.050

1.000

0.945

0.900

0.835

0.775

0.705

0.603

0.545

0.445

Where cables are to be grouped in free air, the following factors should be applied:

No. of Cables in Group

2

3

4

5

6

7

8

Correction Factor

0.80

0.70

0.70

0.60

0.56

0.50

0.50

Ambient air temperature 40°C
Conductor operating temperature 90°C

Elektrische Eigenschaften

Resistance Values (ohms per kilometre)

Nominal Dirigent Bereich

Nominal Dirigent Strandung

Max. DC-Widerstand at 20°C

Max. Dauerstrom Bewertungen

(BS6195) Types

mm2

#/mm

ohms/Km

Amp

0.50

16/0.20

38.2000

13

0.75

24/0.20

25.4000

17

1.00

32/0.20

19.1000

20

1.50

30/0.25

13.0000

26

2.50

50/0.25

7.8200

36

4.00

56/0.30

4.8500

49

6.00

84/0.30

3.2300

64

10.00

80/0.40

1.8500

90

16.00

126/0.40

1.1800

120

25.00

196/0.40

0.7570

163

35.00

276/0.40

0.5380

203

50.00

396/0.40

0.3750

267

70.00

360/0.50

0.2640

324

95.00

475/0.50

0.2000

391

120.00

608/0.50

0.1560

455

150.00

756/0.50

0.1260

525

185.00

925/0.50

0.1030

600

240.00

1121/0.50

0.0778

725

300.00

1525/0.50

0.0623

840

400.00

2013/0.50

0.0472

1010

630.00

2160/0.60

0.0292

1450

 

Nominal Dirigent Bereich

Nominal Dirigent Strandung

Max. DC-Widerstand at 20°C

Max. Dauerstrom Bewertungen

(BS6195) Types

mm2

#/mm

ohms/Km

Amp

0.50

16/0.20

38.2000

13

0.75

24/0.20

25.4000

17

1.00

32/0.20

19.1000

20

1.50

30/0.25

13.0000

26

2.50

50/0.25

7.8200

36

4.00

56/0.30

4.8500

49

6.00

84/0.30

3.2300

64

10.00

80/0.40

1.8500

90

16.00

126/0.40

1.1800

120

25.00

196/0.40

0.7570

163

35.00

276/0.40

0.5380

203

50.00

396/0.40

0.3750

267

70.00

360/0.50

0.2640

324

95.00

475/0.50

0.2000

391

120.00

608/0.50

0.1560

455

150.00

756/0.50

0.1260

525

185.00

925/0.50

0.1030

600

240.00

1121/0.50

0.0778

725

300.00

1525/0.50

0.0623

840

400.00

2013/0.50

0.0472

1010

630.00

2160/0.60

0.0292

1450