TUNNEL CABLES |
||||||||||
TUNNEL CABLES
(N)TSCGEWöU-TBM
Application
The cables are suitable for reeling power supply cables for TBM’s machines and in underground mines for tunnel
constructions.
STANDARDS
construction | DIN VDE 0250-813 |
General Requirements |
DIN VDE 0250-1 |
Guide Use |
DIN VDE 0298-3 |
Electrical Tests |
DIN VDE 0472-501, 503, 508 |
Non-Electrical Tests |
DIN VDE 0472-401. 402,602,303, 615 |
Under Fire Condition Tests |
DIN VDE 0472-803, 804 |
Flame Retardant |
VDE 0482-332-1-2,DIN EN 60332-1-2,IEC 60332-1 |
Oil Resistant |
HD/EN/IEC 60811-2-1.,DIN VDE0473-811-2-1 |
CABLE CONSTRUCTION
conductor |
Flexible Tinned Electrolytic copper conductor DIN VDE 0295 Class 5 |
Insulation |
3Gl3 type EPR compound |
Electrical Field Control |
Inner and Outer semiconductive layer of semiconductive rubber |
Control core |
Tinned Copper conductor with semiconductive layer |
Protective-Earth conductor |
Tinned Copper/ Textile braiding combinated cores laying concentric around each power core. |
Core Identification |
Main Cores: Natural coloring with black semiconductive rubber. |
Lay Up |
Three main conductors laid-up with three control cores in the outer interstice |
Inner Sheath |
GM1b Type EPR Compound |
Screen |
Overall concentric lay of copper wire spinning. |
Outer Sheath |
5GM5 Type elastomer compound. Red |
Technical Characteristics
Rated Voltage |
3.6/6 KV |
6/10 KV |
8.7/15KV |
12/20 KV |
18/30 KV |
AC Test Voltage |
11KV |
17KV |
24KV |
29KV |
43KV |
Max.Permissible Operating Voltage AC |
4.2/7.2 KV |
6.9/12KV |
10.4/18 KV |
13.9/24KV |
20.8/36 KV |
Max.Permissible Operating Voltage DC |
5.4/10.8 KV |
9/18 KV |
13.5/27 KV |
18/36 KV |
27/54 KV |
Min Bending Radius |
VDE 0298-3 Tab 3 |
||||
Current Carrying Capacities |
VDE 0298-4 |
||||
Working Temperature |
|||||
Fixed |
-40°C-+80°C |
||||
Mobile |
-25°C-+80°C |
||||
Max.Tensile Load Of cable |
15N/mm² |
||||
max.torsion |
25°/m |
||||
Trawl Speed For Tunnelling App |
Max.30 m/min |
||||
Minimum Distarce For Change Of Direction |
20×D |
Dimensions And Weight
3.6/6 KV
Cross Section (mm²) |
Overall Diameter |
Appro. Weight (kg/km) |
3x25+3x16/3E+3x2.5ST+6ÜLKON |
42.2-45.4 |
2770 |
3x35+3x25/3E+3x2.5ST+6ÜLKON |
46.8-50.0 |
3200 |
3x50+3x25/3E+3x2.5ST+6ÜLKON |
50.1-53.2 |
4040 |
3x70+3x35/3E+3x2.5ST+6ÜLKON |
54.6-57.7 |
5035 |
3x95+3x50/3E+3x2.5ST+6ÜLKON |
56.4-60.5 |
6270 |
3x120+3x70/3E+3x2.5ST+6ÜLKON |
64.0-68.0 |
7400 |
6/10 KV
Cross Section (mm²) |
Overall Diameter |
Appro. Weight (kg/km) |
3x25+3x16/3E+3x2.5ST+6ÜLKON |
45.5-48.2 |
2975 |
3x35+3x25/3E+3x2.5ST+6ÜLKON |
47.8-51.0 |
3420 |
3x50+3x25/3E+3x2.5ST+6ÜLKON |
50.7-54.9 |
4260 |
3x70+3x35/3E+3x2.5ST+6ÜLKON |
57.2-61.4 |
5270 |
3x95+3x50/3E+3x2.5ST+6ÜLKON |
61.1-65.3 |
6540 |
3x120+3x70/3E+3x2.5ST+6ÜLKON |
65.1-69.3 |
7840 |
12/20 KV
Cross Section (mm²) |
Overall Diameter |
Appro. Weight (kg/km) |
3x25+3x16/3E+3x2.5ST+6ÜLKON |
51.1-55.3 |
3600 |
3x35+3x25/3E+3x2.5ST+6ÜLKON |
54.0-58.2 |
4140 |
3x50+3x25/3E+3x2.5ST+6ÜLKON |
59.4-63.6 |
5030 |
3x70+3x35/3E+3x2.5ST+6ÜLKON |
64.2-68.4 |
6200 |
3x95+3x50/3E+3x2.5ST+6ÜLKON |
69.2-73.8 |
7520 |
3x120+3x70/3E+3x2.5ST+6ÜLKON |
73.6-77.8 |
8740 |